Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Regulations; Warranty And Service; Installation - NARDI COMPRESSORI DRYER 400 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 12
2

SAFETY REGULATIONS

SAFETY REGULATIONS FOR THE OPERATOR AND
2.01
FOR THE PROPER USE OF DRYER 400
The operator of DRYER 400 must have technical knowledge on the relevant safety regulations and be familiar with the operation
of the machine perfectly. In the case of delegation of work, the operator must inform the next operator of all of the operations
required for the proper use of the machine
The compressor draws air from the surrounding environment (the operator must make sure it is devoid of fumes and / or harmful gases) and passing through
a suction filter begins the cycle of compression/filtering up to the tank. Moreover, it is necessary to install an 8-bar safety valve with a flow rate of not less than
400 l/min on the system under pressure after the DRYER.
SAFETY ESSENTIALS
2.02
Before using the DRYER 400 please read carefully the following information
- Intake air should not be stale or contaminated, the compressor should not be placed in areas where there is dust, danger of explosion, corrosion or fire.
- Make sure that at the time of service or when you want to replace spare parts on the compressor it is not pressurized and the power plug is disconnected
from the power line.
- Replace filter air cleaning parts only with original products.
- When the compressor/dryer is not in use, turn off the power. Never tug on the cable but rather pull the plug to disconnect it from the outlet. Make sure that
the cable does not pass over sharp edges or bend at a sharp angle (in this case use an extension).
- Periodically check the general conditions, especially near the joints, and if small defects are present proceed to the replacement of defective parts.
- Periodically check connections for leaks.
- Repair and replace any damaged part only with original spare parts.
- Do not modify the machine except with express written authorization from the manufacturer.
- When starting the machine, make sure people are not in contact with it.
- The operator's and maintenance manual must be available at all times. Put it in an easily accessible place near the machine and protect it from damage.
- All maintenance and repair tasks on the machine, must be performed by qualified personnel.
- Never exceed the maximum working pressure of 10 bar.
3

WARRANTY AND SERVICE

WARRANTY OF DRYER 400
3.01
The manufacturer warrants the DRYER 400 for a period of twenty four months from the date indicated on the label on the DRYER.
During the time of production and testing a label is put on the machine showing that it is in conformity with the standards of the European Union showing the
CE marking. The warranty is voided if this label is by any reason removed or altered in any way.
For the warranty to be valid, it is necessary that the has complied with the provisions of the contract and that the DRYER
400 has been used as specified and has not been altered or modified without the agreement and confirmation of the manufacturer.
The warranty is not applicable when:
· The machine has not been used properly (as indicated in this manual)
· Non-guaranteed consumable materials and materials of periodic maintenance are used, particularly if used improperly.
- Non original spare parts and replacements are used.
· Gases other than air are used
SERVICE OF DRYER 400
3.02
To order spare parts please contact or visit our dealers. In case of difficulty in finding a spare part, contact directly NARDI
COMPRESSORI. We are available for any queries or further information and we will put you in contact with skillful
technical staff to help you. If you need service or assistance, please contact out dealers in your area.
4

INSTALLATION

INSTALLATION
4.01
In order to have a good air quality, it is very important to place the DRYER 400 in a cool and dry place,
protected from the elements. The minimum and maximum operating temperatures can be found on the table with the technical
details, in section 1.05 above.
We do not recommend placement in an outdoor environment.
PLACEMENT ON THE COMPRESSOR
4.02
The DRYER 400 can be used ONLY with compressors OIL-FREE.