Imager Compliance and Precaution
This product complies with IEC 62471: 2006-07 for LED safety.
The scan engine mounted in 1D and 2D configurations are classified as: Exempt.
The scan engine mounted in HP configuration is classified as: Risk group 1.
Exempt: No photobiological hazards based on the limits defined in the standard.
Risk group 1: Low-risk—does not pose a hazard based on normal behavorial limitations on exposure.
U.S.A. Digital Emissions Compliance
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) This device must accept any interference received, including interference that can cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the radio or television receiving antenna.
Increase the separation between the computer equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the radio or television receiver is connected.
Consult the dealer or an experienced radio television technician for help.
Canadian Digital Apparatus Compliance
This device complies with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) This device must accept any interference received, including interference that can cause undesired operation.
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
For Users in Europe
Imager Compliance and Precaution
LASER Safety—IEC 60825-1: 2007/EN 60825-1: 2008-05: Class 2 (1 mW, 650 nm) - applies to HP configuration only.
If applicable, this product will be provided with a set of laser safety labels illustrated on the last page (s) of this document. If the proper label
language is not installed on the device, locate and apply the appropriate label over the existing label.
LED Safety—IEC 62471: 2006-07/EN62471: 2008: The scan engine mounted in 1D and 2D configurations are classified as: Exempt. The scan
engine mounted in HP configuration is classified as: Risk group 1.
Exempt: No photobiological hazards based on the limits defined in the standard.
Risk group 1: Low-risk—does not pose a hazard based on normal behavorial limitations on exposure.
EU - R&TTE Declaration
Intermec Technologies Corporation declares that this module is in compliance with the essential requirements and other relevant provisions
of R&TTE Directive (1999/5/EC).
ETSI EN 300 328
ETSI EN 301 489
EN 60950-1
EN 62311
The transmitter module's output power is 41 mW EIRP. The products using this module are intended for business and industrial
environments.
A copy of the EU Declaration of Conformity is located at: www.intermec.com\support\manuals.
This product is marked with this logo and uses radio frequency bands that are harmonized throughout the European
Community and others as noted in the table below.
This equipment may be operated in the following countries without restriction:
AT
BE
CY
CZ
MT
NL
PL
PT
AL
BA
Restrictions (Revision ERC/REC 70-03 E 2012-07, Annex 3 Band A)
NO
This subsection does not apply for the geographical area within a radius of 20 km from the center of Ny-Ålesund.
RU
1. SRD with FHSS modulation
1.1. Maximum 2.5 mW e.i.r.p.
1.2. Maximum 100 mW e.i.r.p. Permitted for use SRD for outdoor applications without restriction on installation height only for
purposes of gathering telemetry information for automated monitoring and resources accounting systems. Permitted to use SRD
for other purposes for outdoor applications only when the installation height is not exceeding 10 m above the ground surface.
1.3.Maximum 100 mW e.i.r.p. Indoor applications
2. SRD with DSSS and other than FHSS wideband modulation
2.1. Maximum mean e.i.r.p. density is 2 mW/MHz. Maximum 100 mW e.i.r.p.
2.2. Maximum mean e.i.r.p. density is 20 mW/MHz. Maximum 100 mW e.i.r.p. It is permitted to use SRD for outdoor applications
only for purposes of gathering telemetry information for automated monitoring and resources accounting systems or security
systems.
2.3. Maximum mean e.i.r.p. density is 10 mW/MHz. Maximum 100 mW e.i.r.p. Indoor applications
2