SF61 Cordless Scanner Compliance Insert
Model 1016SP01B
For Users in English-Speaking Regions (en)
Caution: This marking indicates that the user should read all included documentation before use. Retain this supplement for future
reference.
Users of this product are cautioned to use accessories and peripherals approved by Intermec Technologies Corporation. The use of accessories
other than those recommended, or changes to this product that are not approved by Intermec Technologies Corporation, may void the
compliance of this product and may result in the loss of the user's authority to operate the equipment.
Battery, Charger, and Power Supply Information
Caution: For use with Intermec battery pack Model 1016AB01 only. No user-serviceable parts.
Caution: The battery pack used with this product may ingnite, create a chemincal burn hazard, explode, or release toxic materials if
mistreated. Do not incinerate, disassemble, or heat above 100°C (212°F). Do not short circuit; may cause burns. Keep away from
children.
Use only Intermec charger Model 074645 and 074646. Use of incorrect charger may present a risk of fire or explosion. Promptly
dispose of used battery pack according to the instructions.
Battery Recycling Information
This product contains or uses a lithium-ion (Li-ion) main battery. When the battery reaches the end of its useful life, the spent
battery should be disposed of by a qualified recycler or hazardous materials handler. Do not mix this battery with the solid
waste stream. Contact your Intermec Technologies Service Center for recycling or disposal information.
Li-ion
Li-ion
Note: In the U.S.A., the EPA does not consider spent Li-ion batteries as hazardous waste.
Radiation Exposure Statement
Warning: This equipment complies with International Commission on Non-Ionizing Radiation Protection (ICNIRP), IEEE C95.1,
Federal Communications Commission Office of Engineering and Technology (OET) Bulletin 65, Canada RSS-102, and European
Committee for Electrotechnical Standardization (CENELEC) limits for exposure to radio frequency (RF) radiation.
Use of antennas and accessories not authorized may void the compliance of this product and may result in RF exposures beyond the limits
established for this equipment.
For North America:
The maximum IEEE C95.1 allowed SAR value is 1.6 W/kg over 1 g of tissue.
Radio Technology
W/Kg
Bluetooth
<1.6
For Europe:
The maximum ICNIRP/CENELEC allowed SAR value is 2.0 W/kg over 10 g of tissue.
Radio Frequency (RF) Exposure and Specific Absorption Rate (SAR) Test Results for Intermec scanner SF61 (1016SP01B):
Bluetooth
<2.0 W/kg (maximum SAR value tested for body-worn operation)
For Users in the U.S.A. and Canada
Laser Compliance and Precaution
The 1016SP01B HP is registered with the CDRH as a Class II LASER Product (21 CFR Subchapter J, Part 1040). This product has a maximum
output of 1 mW at 650 nm.
Caution: There are no user serviceable parts inside the 1016SP01B. Use of controls or adjustments, or performance of procedures
other than those specified herein, may result in hazardous laser light exposure of up to 1 mW at 650 nm.
Note: There are no controls or adjustments provided for routine operation or maintenance of the 1016SP01B.
CAUTION
CLASS 2 LASER LIGHT
WHEN OPEN.
IEC 60825-1: 2007
DO NOT STARE
EN 60825-1: 2007
INTO BEAM.
LASER LIGHT - DO NOT STARE INTO
BEAM CLASS 2 LASER PRODUCT
1mW 630 - 680nm
Maximum SAR value tested or comment
- For body-worn operation.
1