Herunterladen Diese Seite drucken

MEDC FL11 Technische Anleitung Seite 5

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Replace the tube assembly onto the cover assembly and secure using the two off M3 nuts and washers.
Ensure the retaining strap is fitted to one of the tube assembly mounting points during re-assembly.
Carefully replace the cover assembly back onto the base, avoiding damage to the mating surfaces. Replace
the 6 off M5 screws (4.0mm /F hexagon key) into the holes in the cover assembly and tighten evenly.
Ensure the O-ring is seated correctly on the cover during re-assembly. Ensure the required maximum gap
of 0.2mm is maintained between the cover and the base once assembled
5.0 CERTIFIC TION/ PPROV LS
IECEx units
Certified to IEC60079-0, IEC60079-1 and IEC60079-31
Ex d unit (IEC certification No. IECEx B S 10.0101)
Ex d IIB Tx (Tamb.) Gb
Ex tb IIIC Tx (Tamb.) Db IP66/IP67
Lamp Power
Gas T-rating (Tx)
10W
5W
Note: For functional purposes the certification labels are marked with a min. ambient temperature of -20°C
N
The IECEx certificate and product label carry the IECEx equipment protection level marking
N
Gb
Db
Where Gb signifies suitability for use in a Zone 1 surface industries area in the presence of gas.
Where Db signifies suitability for use in a Zone 21 surface industries area in the presence of dust.
TEX units
Certified to EN60079-0, EN60079-1 and EN60079-31
Ex d unit ( TEX certification No. B S99 TEX2195)
Ex d IIB Tx (Tamb.) Gb
Gas T-rating (Tx)
Ex tb IIIC Tx (Tamb.) Db IP66/IP67
Lamp Power
10W
5W
© MEDC 2015
Dust T-rating (Tx)
T4
T5
Gas T-rating (Tx)
Dust T-rating (Tx)
T6
T4
T5
T5
T6
T6
T5
T6
Dust T-rating (Tx)
T4
T5
Gas T-rating (Tx)
Dust T-rating (Tx)
T6
T4
T5
T5
T6
T6
T5
T6
T110°C
T85°C
T70°C
T110°C
T85°C
T85°C
T70°C
T70°C
T85°C
T70°C
T110°C
T85°C
T70°C
T110°C
T85°C
T85°C
T70°C
T70°C
T85°C
T70°C
Ambient temp range (Tamb.)
(-55°C to +70°C)
(-55°C to +55°C)
Ambient temp range (Tamb.)
(-55°C to +40°C)
(-55°C to +70°C)
(-55°C to +70°C)
(-55°C to +55°C)
(-55°C to +55°C)
(-55°C to +40°C)
(-55°C to +70°C)
(-55°C to +55°C)
Ambient temp range (Tamb.)
(-55°C to +70°C)
(-55°C to +55°C)
Ambient temp range (Tamb.)
(-55°C to +40°C)
(-55°C to +70°C)
(-55°C to +70°C)
(-55°C to +55°C)
(-55°C to +55°C)
(-55°C to +40°C)
(-55°C to +70°C)
(-55°C to +55°C)