To make adjustment using the signal sound
1.
Turn on the DIP Switch #3 of the receiver.
Select one of 3-sound level outputs.
-
Realign/Poor: Beep-beep-beep
-
Fair: Beep-beep-beep-beep-beep
-
Good/Excellent: Beep~~~~~~~~~~~~
After the adjustment, make sure to turn off the switch.
2.
To make adjustment using the voltmeter
1.
Make adjustment as necessary using the voltmeter.
Measure the output volt at DC 10V DC.
2.
Insert the test probe.
It is labeled in either "Monitor".
3.
Check the product status according to the voltage.
Measured Voltage
2.5V or higher
0.5V ~ 2.4V
0.5V or lower
Z6806119901A-SIA-0100Q,0200Q.ind8 8
Z6806119901A-SIA-0100Q,0200Q.ind8 8
Alignment
Excellent
Good
Poor, to be adjusted
English _8
Voltmeter
(10V DC)