5.1.2 Data Lines
The terminal compartment for the data lines is an Ex e compartment (increased safety).
Ex e terminal compartment for the P-Ex1002MC, P-Ex1003GX2, P-Ex1005TX data lines
For channels 1 to 5 (P-Ex1005TX only), the following assignment applies:
Terminal:
1
2
3
4
5
6
7
8
•
2
0.4 - 0.64mm
•
Max. 1 line per terminal
•
The contacting of the copper conductors is done using a conventional LSA+ punch
down tool
•
Tighten the retaining clip with a torque of 1.2Nm
Ex e terminal compartment for the P-Ex1002MC and P-Ex1003GX2 optical data lines
Terminal:
1
1
2
2
•
Connect the optical interfaces using prefabricated optical fiber cables
•
Plug type ST
•
Recommended fiber type: Multimode 50/125µm
Page | 28
Figure 6
Designation:
D0 +
D0 -
D1 +
D2 +
D2 -
D1 -
D3 +
D3 -
/ 26AWG-22AWG conductor cross section, rigid
Designation:
RX
Receive Ch1
TX
Transmit Ch1
RX
Receive Ch2
TX
Transmit Ch2
Figure 7
Figure 8