Never touch the plug with wet hands. Never pull out the plug from the socket using the cable - al-
ways pull on the plug. Keep the product, plug and all cables away from open fires and hot surfaces.
Lay the cable so that it does not pose a tripping risk and do not pla ce it under the ground. Lay cab-
les in such a way that they will not be damaged by lawn mowers and other similar devices. Do not
kink the cable and do not lay it over sharp edges. Do not use an extension cable, multiple socket
adapters or other adapters.
4.

Technical Data

Connection:
Isolation transformer:
Temperature sensor
Temperature range:
Water connection:
Tolerance:
5.
Operation / Features Display
Status lndicator GREEN LED: Standard circulation = if the desired temperature is the same as or
lower than water temperature in the pool.
Status lndicator RED LED: Solar circulation = if the temperature measured by temperature sensor
2 is higher than the desired temperature that has been set.
6. Streamflow Status
There are three streamflow status:
1
When St>Pt and Tt>Pt; Then B opens and C is closed; The water flows through the solar
collector;
2
When St>Pt and Tt≤Pt; Then B is closed and C opens; The water won't go through the
solar collector;
3
When St≤ Pt; Then B is closed and C opens; The water won't go through the solar collector.
St means the setting temperature that you want to have in the pool; Tt means the water temperatu-
re in the outlet of solar collector; Pt means the water temperature in the pool.
26
230 V/50 Hz
24 V
1: Integrated into the 3-way valve temperature sensor
2: 10 m cable with integrated sensor
18° C - 40°C
1 ½" internal thread
+/- 1 °C
Current Temp.: shows the current temperature of the water
(temperature sensor integrated into the 3-way valve)
Desired Temp.: enables the temperature to be set to the desi-
red level from 18° C to 40° C.
Press "+" or "-" to set the desired temperature. The tem perature
that has been set will then flash for 5 seconds and will automa-
tically change back to the actual water temperature.