          Safety Summary
          To avoid potential hazards, use this product only
          as specified.
          To avoid fire or personal injury
          Ground the product.
          For safe operation, the oscillo-
          scope chassis must remain at earth ground poten-
          tial even when operating from battery power. This
          protection is provided when you attach the Tektro-
          nix-supplied grounding wire from the terminal on
          the rear panel of the oscilloscope to earth ground.
          If you use a different grounding wire, it must be
          18 gauge or larger.
          Recharge battery properly.
          Recharge the battery
          pack only for the recommended charge cycle at
          the recommended temperature.
          Use proper battery charger.
          Use only the
          TDS3CHG or the TDS3000/TDS3000B series
          oscilloscope to charge the TDS3BATB battery
          pack.
          Do not operate without covers.
          Do not operate this
          product with covers or panels removed.
          Do not operate with suspected failures.
          suspect there is damage to this product, have it
          inspected by qualified service personnel.
          Provide proper ventilation.
          Refer to the installation
          instructions in the TDS3000/TDS3000B Series
          User Manual for details on installing the product
          so it has proper ventilation.
          Do not operate in wet/damp conditions.
          Do not operate in an explosive atmosphere.
          Keep product surfaces clean and dry.
          Safety terms in this manual
          These statements identify
          CAUTION.
          conditions or practices that could result in
          damage to the equipment or other property.
          Safety symbols on the product
          Double
          CAUTION
          Insulated
          Refer to Manual
          Battery recycling
          This product contains lithium-ion (Li-Ion)
          batteries which must be recycled or disposed of
          properly at the end of product life. There may be
          specific legal requirements for battery collection
          and disposal in your community. Contact your
          local electronics recycler, relevant legal authority,
          or your Tektronix representative for assistance in
          recycling of the battery pack.
          Li-ion
          Transportation and Lithium-Ion Batteries
          Each TDS3BATB lithium-ion battery pack
          contains less than 8 grams of lithium, with
          individual cells each containing less than
          1.5 grams of lithium, as measured by International
          Civil Aviation Organization (ICAO) standards.
          Consult your air carrier for applicability and
          determination of any special lithium-ion battery
          transportation requirements.
          Description
          If you
          The TDS3BATB is for use with
          TDS3000/TDS3000B Series oscilloscopes. The
          14.4 VDC battery pack consists of an array of
          Lithium-ion battery cells with a built-in charger
          and fuel or battery gauge.
          Firmware Requirements
          The firmware in your TDS3000/TDS3000B series
          oscilloscope must be Version 3.26 or above for the
          battery gauge to work properly.
          For your convenience, the latest version of the
          instrument firmware is included with the
          TDS3BATB battery pack. If you need to update
          your firmware, follow the installation instructions
          that are included with the firmware.
          You can also download the firmware from the
          Tektronix Web site at www.tektronix.com.
          Protective Ground
          Removing the Battery Pack
          (Earth) Terminal
          To remove the battery pack, follow these steps:
          1. Open the battery compartment door.
          2. Raise the handles on each side of the battery
          pack and use them to pull the battery pack out
          of the oscilloscope.

          Werbung

          Inhaltsverzeichnis
          loading

          Inhaltszusammenfassung für Tektronix TDS3BATB

          • Seite 7 Wenn Sie vermuten, daß das Produkt 071-0900-02 beschädigt wurde, lassen Sie es von einem qualifi- Der TDS3BATB wurde für den Einsatz in zierten Wartungstechniker untersuchen. Oszilloskopen der Serie TDS3000/TDS3000B entworfen. Das 14.4 VDC Akkupack besteht aus Sorgen Sie für ausreichende Luftzufuhr.
          • Seite 8: Garantie

            Tektronix- Kontaktinformationen Akku benutzt wird. Akku wird mit dem externen 6 Stunden Tektronix, Inc. Kalibrieren Sie das Gerät TDS3BATB alle 45 Ladegerät TDS3CHG geladen 14200 SW Karl Braun Drive Tage während des regulären Betriebs. P.O. Box 500 Beaverton, OR 97077 Um die Kontrollanzeige zu kalibrieren, führen Sie...

          Inhaltsverzeichnis