Location and Function of Parts

1
Indicator A
Front panel
S
A
O
Rear panel
5
Cover plates
6
y (signal ground) terminal
7
STATUS OUT connector
1 Indicator A
Lights in green when power unit A is turned on.
Flashes in red in the following cases:
• The temperature inside power unit A has risen to a
specified level.
• The ventilation fans have stopped rotating.
• Trouble occurs with the output voltage of power unit
A.
• When both power units A and B (BKPF-PS50A
Backup Power Supply Unit, optional) are installed
and only power unit B is turned on.
• A voltage overload has occurred.
4 (GB)
2
Indicator B
POWER
POWER
I
I
B
O
4
POWER B switch
3
POWER A switch
DIGITAL INTERFACE UNIT
4
(ISR)
3
y
2
1
STATUS OUT
REF IN
REMOTE
ROUTING SWITCHER
2 Indicator B
Lights in green when power unit B is turned on.
Flashes in red in the following cases:
• The temperature inside power unit B has risen to a
specified level.
• The ventilation fans have stopped rotating.
• Trouble occurs with the output voltage of power unit
B.
• When both power units A and B are installed and
only power unit A is turned on.
• A voltage overload has occurred.
3 POWER A switch
Turns on and off power unit A.
4 POWER B switch
Turns on and off power unit B.
PFV-HD50A
⁄AC IN
A
B
8
~AC IN B connector
9
~AC IN A connector
0
ROUTING SWITCHER connector