WARNINGS
.
q
This handbook, which is divided into two parts, is an essential
integral part of the product. Please read all the information
carefully as it contains important indications on safety during
installation and use. Store this handbook in a safe place for
future reference. The boiler must be installed in compliance
with current regulations and following the manufacturer's in-
structions. Wrong installation may cause injury or damage,
for which the manufacturer can not be held liable.
q
Unwrap all the parts and check the contents.
q
In case of doubt, do not use the boiler and return it to the sup-
plier.
q
Packaging elements, such as wooden crates, nails, staples,
plastic bags and foam plastic, are a hazard and must not
be left within the reach of children.
q
This boiler must only be used for the purpose for which it was
designed and built. Any other use is considered improper and
thus hazardous. The manufacturer can not be held responsi-
ble for damage or injury caused by improper or unreasonable
use.
q
Before carrying out any cleaning or maintenance operations,
always disconnect the boiler from the mains supply.
2

GENERAL DESCRIPTION

.
(Fig. 1)
This boiler, which is made up of cast iron wet chamber elements and
designed to operate with a vacuum for models with 3, 4 and 5 ele-
ments and with pressure for subsequent models, fully comply with
the latest heat engineering principles.
In particular, they are very popular due to their high output and con-
siderable cost saving, ease of installation and maintenance, and the
fact that they can use any type of approved burner.
The boiler described in this manual is designed so that it can be ser-
viced from the front. The burner is mounted on the door which can
open to the right or left as required.
NOTES. . The terms right and left, front and back refer to a person
facing the boiler from the door side.
. The numbers in the descriptions correspond to the num-
bers shown on the exploded diagrams for assembly and
spare parts.

GENERAL RULES

q
Do not obstruct the air intakes or ventilation pipes.
q
If the boiler malfunctions or breaks down, deactivate it imme-
diately. Never attempt to repair it yourself. A professionally
qualified person needs to be called in. If any parts need re-
pairing, this must be done by a servicing centre authorised
by the manufacturer, using original spare parts. If this is not
done, safe operation of the boiler may well be affected.
q
In order to ensure efficiency and correct operation, it is vital to
follow the manufacturer's instructions. The boiler must be
serviced periodically by a properly qualified person. If you de-
cide not to use the boiler any longer, all parts that are likely to
cause a hazard must be rendered harmless.
q
If the boiler is to be sold or transferred to another owner, or if
you move and leave the boiler where it is, always check that
the handbook remains with the boiler so that it can be con-
sulted by the new owner or installer.
q
Original accessories and spare parts must always be used for
boilers with optionals or kits (including electrical ones).
q
WARNING. If there is the risk of freezing, always take the ne-
The shell of the boiler is comprised of:
. A front element equipped with inspection holes for cleaning pur-
poses and burner supports both equipped with hinges.
. Intermediate elements with a special configuration to ensure con-
siderable heat exchange. The number of elements varies depend-
ing on the boiler capacity.
. Terminal element for connection to the delivery and return pipes
and flue gas exhaust piping.
The combustion chamber "A" (or furnace) is the horizontal cylindri-
cal type, situated in the bottom of the boiler. The flue gases flow
through the chamber, come into contact with the bottom of the fur-
nace, are deflected into the side passages as far as the front door,
which convey them into the inner passages of the elements before
entering the exhaust pipe.
This circuit with three combustion gas passes means silent opera-
tion and optimal heat exchange.
The boiler shell is thermally insulated by means of a thick layer of
fibreglass applied directly onto the shell and the terminal element,
and another layer on the top.
The doors are lined with thick heat-resistant insulation material
which maintains the external temperature well below the level pre-
scribed by EN 303. This gives extremely limited heat loss by radia-
tion.
The jacket is the modular type made of oven painted steel sheet. It is
extremely functional and ensures easy access to front doors simply
by removing the initial panel and without requiring any tools.
The technical features of the boiler are shown on the rating plate be-
low.
MANUFACTUR-
F1260227
2
cessary measures, such as adding antifreeze or
emptying the system.
ER
SERIAL
NUMBER

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Lgc3Lgc4Lgc5Lgc6Lgc7Lgc8

Inhaltsverzeichnis