Herunterladen Inhalt Inhalt Diese Seite drucken

Declaration Of Conformity - V2 TYPHOON Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

3. SENSOR THRESHOLD LEVELS
To display and modify the threshold levels of the various sensors,
follow this procedure:
a) WIND Sensor
CAUTION: To cause the sunshade to close, the wind sensor
must detect a value greater than the set threshold for at least 5
seconds. Closure of the sunshade due to strong wind causes the
system to block for 8 minutes.
1. Press P2: the WIND LED will turn on, identifying the wind
sensor, and at the same time the LED that displays the sensor
threshold level turns on:
LED 1 = level 1 = 10 km/h (default value)
LED 2 = level 2 = 15 km/h
LED 3 = level 3 = 20 km/h
LED 4 = level 4 = 30 km/h
LED 5 = level 5 = 40 km/h
2. To change the set level, press P1 a number of times until the
level you want is displayed (once level 5 is reached, the next
time it is pressed it restarts from level 1).
b) SUN Sensor
CAUTION: To cause the sunshade to open, the sun sensor
must detect a value greater than the set threshold for at least 8
minutes.
To cause the sunshade to close, the sun sensor must detect a
value less than the set threshold for at least 8 minutes.
1. Press P2 twice: the SUN LED will turn on, identifying the sun
sensor, and at the same time the LED that displays the sensor
threshold level turns on:
LEDs OFF = sensor disabled
LED 1 = level 1 = 2 klux
LED 2 = level 2 = 5 klux
LED 3 = level 3 = 10 klux (default value)
LED 4 = level 4 = 20 klux
LED 5 = level 5 = 40 klux
2. To change the set level, press P1 a number of times until the
level you want is displayed (once level 5 is reached, the next
time it is pressed it restarts from level 1).
c) TEMPERATURE Sensor
This function allows the temperature level below which the
device must not open the sunshade, even if the light intensity is
greater than the threshold level set.
This function is very useful in countries with cold climates, where
it is often sunny but very cold. Under these conditions it is not
necessary that the sunshade open, which would prohibit the
sun's rays from heating the inside space.
1. Press P2 three times: the TEMP LED will turn on, identifying
the temperature sensor, and at the same time the LED that
displays the sensor threshold level turns on:
LEDs OFF = sensor disabled
LED 1=Level 1 = sensor disabled (default value)
LED 2 = Level 2 = 0 °C
LED 3 = Level 3 = 5 °C
LED 4 = Level 4 = 10 °C
LED 5 = Level 5 = 15 °C
2. To change the set level, press P1 a number of times until the
level you want is displayed (once level 5 is reached, the next time
it is pressed it restar

DECLARATION OF CONFORMITY

V2 SPA herewith states that the TYPHOON models
are in accordance with the following EEC directive:
2004/108/CEE
EMC directive
2006/95/CEE
Electrical safety directive
99/05/CEE
Radio directive
Racconigi, 02/02/2010
V2 SPA legal representative
Cosimo De Falco

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für V2 TYPHOON

Inhaltsverzeichnis