CONNECTION FOR ZEPRO
Connection for Zepro
RECEIVER
MODULE
ANTENNA
NO = NO contact
NC = NC contact
COM = Common contact
Fig.1 Connection bridge
+
4 3 2 1
Standard there is no ground (-) connection in the 7-pole socket.
It is important to make a stable ground (-) connection.
Connect the ground wire preferably on the (-) pole of the battery.
Connection
7-pole
receiver
connector
+ 10-30 VDC
4
Grey
- GND
7
Black
NO1
1
Yellow
NO3
3
White
LEARNING BUTTON
MICROCONTROLLER
(MCU)
CHIP
RELAY 4
NO/NC
Connection bridge Fig. 1
NO4 COM4 NC4
NO3 COM3 NC3
(3) White
Connection
point tail lift
+
-
E
B
LEARNING
INDICATOR
10-30 VDC
RELAY 3
RELAY 2
NO/NC
NO/NC
NO2 COM2 NC2
(1) Yellow
Male
Function Diagram
7-pole
connector
+
(7) Black
GND
-
RELAY 1
NO/NC
NO1 COM1 NC1
+ (4) Grey
1
2
6
7
3
5
4
Connection
point tail lift
1
E
3
B
Zepro_2bt_RCC_V.3.0.pdf
Connection diagrams 33

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis