Herunterladen Inhalt Inhalt Diese Seite drucken

Connection For Dhollandia - Haco 4552700H Handbuch

Inhaltsverzeichnis

Werbung

CONNECTION FOR DHOLLANDIA

Connection for Dhollandia - hydraulic
RECEIVER
MODULE
ANTENNA
Connection bridge Fig. 1
NO = NO contact
NC = NC contact
COM = Common contact
Fig.1 Connection bridge
+
4 3 2 1
Standard there is no ground (-) connection in the 7-pole socket.
It is important to make a stable ground (-) connection.
Connect the ground wire preferably on the (-) pole of the battery.
Connection
7-pole
receiver
connector
+ 10-30 VDC
6
Red
- GND
7
Black
NO1
5
Green
NO2
3
White
NO3
3
White
NO4
2
Brown
28 Connection diagrams
HYD (HYDRAULIC) CONNECTION
LEARNING BUTTON
MICROCONTROLLER
(MCU)
CHIP
RELAY 4
NO/NC
NO4 COM4 NC4
NO3 COM3 NC3
(2) Brown
(3) White
Connection
point tail lift
+
-
R
H
H
DB
LEARNING
INDICATOR
10-30 VDC
RELAY 3
RELAY 2
NO/NC
NO/NC
NO2 COM2 NC2
(5) Green
Male
Function Diagram
7-pole
connector
5 + 3
3 + 2
Dhollandia_hydr_2bt_RCC_V.3.0.pdf
+
GND
-
RELAY 1
NO/NC
NO1 COM1 NC1
(6) Red +
1
2
6
7
3
5
4
Connection
point tail lift
R + H
H + DB
(7) Black

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis