Provide an air gap of at least 58mm (A) under the unit;
Provide venting to the outside of at least Ø12mm and max Ø25mm (B);
Make sure the gas dispersal hole can never be blocked.
Position the unit so it is centred and level in the cut-out. There must also be a gap of 2-3mm
between the appliance and sides of the cut-out;
Attach the SHB353 or SCU353 to the worktop as shown.
SHB353/SCU353
1
4.2mm

5. Connecting gas

Connect the gas to the Ø8mm gas inlet;
Use only metal gas pipes in accordance with the requirements of EN1949.
Never use rubber tubing.
The burners have a fixed air/fuel mixture. When using propane, the flames burn quietly
with a blue-green color and no yellow at the tip. With butane, the flames have yellow tips.
The yellow colour of the flames increases slightly as the burner heats up.
6
B
2
3
4
7
6
A
1. Surface mounting bezel
2. Pressing
3. Glass lid
4. Screw fixing cap
5. Bump stop
5
6. Wood screw
7. Worktop