Instructions for Use:
With an easy pressure on the top, TriGasAlarm is switched on.
After that TriGasAlarm goes through a self-test and checks the
correct function of electronics and sensor. The procedure is indi-
cated through the flashing LEDs during the flashing of the green
LEDs TriGasAlarm goes into the calibration of the sensor. This
phase lasts up to two minutes. The calibration is completed as
soon as the green LED constantly shines. To switch the device
10
off, keep the switch pressed for approx. 2 seconds.
Brightness of the green LED:
To dim the green LED, press shortly on the power switch. If you
press the power switch again (shortly) the brightness will be
high again.
larm
If TriGasAlarm detects a gas concentration in the environment-
air, the appliance generates a silent prealarm, indicated by a
flashing red and green LED for 20 seconds. During this time Tri-
GasAlarm will check the concentration of the gas detected. If
the concentration is the same or higher an Alarm will be created.
The Alarm is indicated through flashing red LEDs light and an
alarm sound.