Herunterladen Inhalt Inhalt Diese Seite drucken

General Maintenance And Cleaning - MARTINDALE M26/400 Bedienungsanleitung

Frischluft system
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
Adjust the vertical position at which the hoses are held together such that when placed over the head the hose assembly does
not slip down over the shoulders. Ensure hoses are not twisted when placed over the head. Fit the full face mask according to
the specific instructions supplied with the mask. Connect the twin air hose to the full face mask by screwing the threaded nut
into the full face mask tightly by HAND.
Inspection & Fit Testing of System
BEFORE USE, THE FOLLOWING CHECKS SHOULD BE CARRIED OUT:
Leak Tightness Testing of Unpowered Apparatus
(With the facemask, double hose, belt bracket donned and reinforced hose fitted)
Block the strainer end of the air supply hose and inhale. This should create a negative pressure inside the mask, thus sucking
the mask onto the face. If this effect is not obtained, re-fit mask and check security of hose connectors then re-test.
Leak Tightness Testing of Powered Apparatus (
With the facemask, double hose with o/f valve, belt bracket donned and reinforced hose fitted)
Disconnect the turbine end of the main air supply hose, block and inhale. This should create a negative pressure inside the
mask, thus sucking the mask onto the face. If this effect is not obtained, re-fit mask and check security of hose connectors then
re-test. If supplying twin users this test should be carried out by both users.

General Maintenance and Cleaning

Double air tube with or without overflow valve
Visually inspect
The valve in the overflow valve assembly of the twin air hose for damage, or distortion.
The underside sealing surface & the O-ring it sits on should be completely free of dust and dirt. (If necessary clean both
surfaces with a soft cloth soaked in clean water and allow to dry).
The hoses for any signs of obvious damage, holes tears etc,
The presence and condition of the rubber 'O'-ring fitted to the plastic 'Y' piece connection of the twin air hose.Replace if
Necessary
Reinforced hose
Check for the presence and condition of both O-rings of the reinforced hose. Replace if necessary.
The security of the hose clamps. The reinforced hose for holes, cuts, tears, abrasions, kinks or flattening.
Full facemask
For maintenance and cleaning of the full face mask refer to the specific supplied instructions.
Mini Turbine Unit
The turbine unit is fitted with a coarse prefilter which is located behind the end plate without the mains cable connection, it can
be accessed by removing the 3 screws. The prefilter consists of a foam disc, it should be checked at minimum of 3 monthly
intervals and if dirty or damaged be replaced. The unit should be cleaned prior to storage and stored in a dry warm atmosphere,
preferably within a protective enclosure.
Electrical safety
Visually inspect
The cable along its length for damage ie torn insulation, exposed conductors etc.
Security and condition of the plug fitted to the cable.
Do not use the unit if any of the above conditions are found
Periodic electrical safety checks must be carried out by a competent person.
Should the turbine unit fail to operate check the supply, the fuse in the plug (230volt version only) and the fuse in the unit
(Replacement fuse. 1.5 amp250V Anti-surge type RS 415-581) WARNING failure to use the correct type of replacement fuse
B
may cause permanent damage to the Unit.
If the unit still fails to operate return to Centurion Safety Products Ltd for repair.
All items should be transported in the packaging originally provided
Cleaning & storage
The system should be cleaned by hand washing with a mild soap (non-detergent) then rinsing with clean water and allowing to
dry naturally. (Do not immerse the turbine unit in water or allow water to enter the unit). Ensure that the complete system is
fully dry before using. The belt bracket and turbine unit should always be stored with protective caps in place.
023-001-058 Mod 3 05/13
Fresh Air Supply System Instructions
Page 3 of 32