ENGLISH
Installation of top/bottom
and side grids
Top/bottom grids, complete (1 pcs). - Cat. no. 34608
Side grids 65mm, complete (1 pcs). - Cat. no. 34609
Side grids 115mm, complete (1 pcs). - Cat. no. 34610
Preparation/installation (fig. 6 & 11)
When installing the Jøtul C 150 grids can be fitted to fill
openings between the hearth and the cassette.
The grids are sold individually so that you may freely
combine grids in order to create the desired width or have
different widths on either side of the cassette.
• The complete top/base grids (x1) are grids supplied with
mounting brackets and screws as shown in fig. 6.
2-4 ribs can be removed using an angle-grinder and used
as a bottom grid. The rest can be used as a top grid and
can be cut if necessary in order to fit under the hearth's
hood.
• Side grids 65mm, complete (1 pcs)
Side grids 115mm, complete (1 pcs)
In addition to top/bottom grids these grids can be used
to fill gaps in the sides of the hearth. Both can be joined
to a grid of the same or different width to create a grid
with the desired overall width. The grid can be angled
up to 45 backwards in order to fit into different hearths
more easily. It can also be cut to the required height.
Figure 11 shows some of the possible grid combinations
and the corresponding resulting external dimensions. In
the majority of cases the grids can be fitted after the
cassette has been correctly positioned in the hearth.
Pre-fitting top/bottom grids
(fig. 6)
Top/bottom grid components
1 pcs
Top/bottom grid
1 pcs
Grid holder, left
1 pcs
Grid holder, right
4 pcs
Flange bolt, M6x25mm
4 pcs
Square nut, M6
4 pcs
Plate screws, countersunk, 4.8x19mm
• Remove the ash retainer, baffle plate, base plate and
burn plate from the cassette if this hasn't already been
done.
• Measure how many grid ribs are to be under the front
of the cassette. The height from the base of the hearth
to underneath the frame should normally be adjusted
to between 40 and 80mm (see fig. 1).
• Cut the grid to the correct height using an angle-grinder.
Important Remember to cut the grid on the opposite
side to the two fixing holes in the corners (fig. 6) that
are used for fitting the grid. There are 10mm spaces
6
between the ribs and each rib is 10mm high.
• With heights from:
40-55mm - use two ribs
55-75mm - use three ribs
over 75mm - use four ribs
• If necessary, at the top of the front, cut as many ribs as
necessary from the top of the grid in order for the grid
to fit under the hearth's hood. There must be at least
two ribs (35mm space) on the top of the front in order
to attach the grid to the grid holder. If there is not enough
space a top grid cannot be fitted. If the 35mm space is
too big the legs can be lengthened in order to reduce
the space or shortened in order to allow space for two
ribs at the top.
If side grids are to be fitted go to section: «Pre-fitting side
grids» before proceeding with fitting top and bottom grids.
Pre-fitting side grids
(fig. 5 and 6)
Side grid components
1 pcs
Side grid
2 pcs
Hinges
1 pcs
Joining pieces
1 pcs
Side grid lock
4 pcs
Flange nuts, M6
4 pcs
Pan head screws, M6x8
4 pcs
Flange bolts, M6x10mm
1 pcs
Washers Ø6.4xØ6.5x1.6
• Cut the top of the side grid to the correct height. The
small nipple of the back of the grid shall be on the lower
section (fig. 5 A).
• Fix the two hinges to the grid holders (fig. 5 B). Use four
pan head screws C on the outside (where the labels
are) and the nuts on the inside. Do not tighten the screws.
The longest protrusion on the grid holder should point
downwards (fig. 6 A).
• Attach the side grid to the hinges using two flange bolts
(M6x10mm) (fig. 5 D). Select the uppermost hole in the
hinge if there are to be two ribs under the front of the
cassette.
Select the middle hole if there are three ribs and the
bottom hole if there are four ribs. Finally, tighten all the
screws in the hinge.
• If the side grids are to be joined with another, use two
joining pieces with flange bolts fig. 5 E.
• On the outermost grid mount the side grid lock
(fig. 5 F). This is attached with a flange bolt, M6x10mm,
and a washer. Note that the tags on the lock are to be
turned inwards towards the middle of the grid (fig. 5G).
Do not tighten the bolt so much that it does not allow
the lock to be slid up and down.
Attach all the side grids before fitting the top/bottom grids.