Bath type priority (Combi only)
Priority type is used to indicate what should be prioritised during the heating phase in
the sauna. The Combi heater has three heating elements that are used to heat the room
and one heating element that is used to produce steam in the water tank. Only three
elements may operate at one time.
The default setting is Automatic. If the set temperature is below 70 °C, steam produc-
tion will be prioritised. This means that two elements will be used to heat the room
and the element in the tank will be used. If there is no water in the tank or the humi-
dity setting (%Rh) has been reached, all three elements will be used to heat the room.
If the temperature setting is above 70 °C, the tank element will not be used until the
room temperature is reached.
Temperature
The heating element in the device is used to heat the room to the set temperature,
regardless of what temperature is defined. The element in the water tank is then acti-
vated.
Humidity
The element in the water tank is activated regardless of the temperature setting. If a
temperature/humidity sensor is fitted the element in the tank will operate until the
defined humidity level is reached. If no temperature/humidity sensor is connected, the
element in the tank will run for 10 minutes initially and then according to the setting.
Cleaning notification (steam products only)
Set the interval that should elapse between reminders to clean the steam generator.
This is not activated by default. This value can be set to between 10 and 3000 operating
hours. When the operating time reaches the defined value, a cleaning reminder notifi-
cation will be displayed every time the steam generator starts. If you answer Yes to the
question, the operating time is reset. The number of cleanings is displayed.
Auto-empty tank (steam products only)
This setting is used to define how long the system should go before the tank automa-
tically empties and then refills with clean water. Various intervals may be required de-
pending on water quality. Intervals of between one and eight hours may be defined. A
notification is displayed on the control panel when the tank auto-empties. When there
are multiple steam generators connected ("multi-steam"), the steam generators empty
sequentially one at a time, to minimise any time without steam.
This function is primarily aimed at systems with longer operating times.
For systems with long operating times, it is recommended that this function is always activated to pre-
vent a high concentration of salts and minerals, which may damage level measurements and correct
in-flow of water.