seconds.
- Enter into "Stand-by" mode and press the [-] button at least 3 seconds.
- On the upper part of the display the message "Set" will be displayed.
- To set the day and time press the [+] button until the bottom part of the
display the message "TED" is displayed (see picture below).
- Press the [Prog] button to enter the editing mode.
- The blinking arrow indicates the currently selected day: Pressing the [+]/[-]
buttons the desired day can then be set.
- Press again the [Prog] button to confirm the selected day. After that, the
procedure for entering the time starts and the display shows the currently
selected time. "Hours": Use the [+] and [-] buttons to set the correct hour
and confirm the selected value pressing the button.
Minutes: Same procedure as for the hours. Confirm the selected value by
pressing the [Prog] button.
- At the end of the procedure, the thermostat returns into "Stand-by" mode.
b) Setting the program for the "Chrono" mode
- Enter into "Stand-by" mode and press the button [-] at least 3 seconds.
- On the upper part of the display the message "Set" will be displayed
- To set the day and time press the button [+] until the bottom part of the
display the message "Prog" is displayed (see picture below).
- Press the [Prog] button to enter the editing mode
- Now a time sequence can be defined for each day of the week.
The procedure starts with day 1, and the desired sequence can be
configured with the [+] and [-] buttons:
For each hour of the day, it is then possible to assign either the
"Comfort" temperature (full bar indication displayed) by pressing the [+]
button or the "Night" temperature (empty bar) by pressing the [-] button (see
picture below). Press [Prog] to confirm the entered configuration for day 1,
and repeat the same procedure for the remaining 6 days of the week.
d. KEY LOCK
It is possible to lock the buttons of the device to avoid inadvertent
modifications of the settings.
Press together the buttons [PROG] for 3 seconds to lock all the buttons
except the [On/Stand-by] button. The key-lock icon is activated on the
display.
To unlock the buttons press again together the [PROG] buttons for 3
seconds.
The key-lock icon disappears on the display:
R_077 REV.8 ott. 2017
e."OpenWindow Detection" function
The "Open Window Detection" function enables detecting of an open window
by sensing a sudden decrease of the temperature in the room. In such a
case, the device deactivates the heating element for a maximum of 30
minutes or until an increase of the room temperature reveals that the window
has been closed.
To activate this function:
- Enter into "Stand-by" mode.
- Press the [+] button for 3 seconds.
- Press the [+] button to activate / deactivate the function
- Press the [Prog] button to commit and return into "Stand-by" mode.
When this function is enabled, the "Open Window" icon on the display is lit.
When the device detects that the window is potentially opened, the "Open
Window" icon starts blinking
When the function is disabled the "Open Window" icon is not shown on the
display:
Note: The device could fail in detecting an opened window e.g. if the
thermostat is located on an isolated area of the room and far from air currents
or if the thermostat is placed close to an external heating source, or if the
temperature variation in the room is too slow.
Note 1: When the symbol "
11. Disposing
At the end of life, this appliance must be deposited in the special collection
centres for recycling, it is not an ordinary household waste. In case of
replacement, the radiator can be sent to your distributor.
Managing in this way, the end of life of a product allows us to preserve our
environment, to limit the use of natural resources.
This symbol on the product indicates the obligation to deliver to
the end of his life to a collection point specialist, in accordance
with Directive 2002/95/EC.
____________________________________
" is on, the heating element is active.
P. 6 di 11