3-8-3 External input

This enables manual ON and OFF forcing functions to be executed from a remote
position, (ref. section 3.7), by means of buttons or switches.
i
Function not available for the SYNCHRO models from GPS or DCF77 input
EN
(the "EXT INPUT" item is not available in the "OPTIONS" menu).
1.
Select the "EXT INPUT" sub-menu using keys
T i m e s e t
2.
Press
OK
3.
Select the channel with the keys
4.
Confirm with
5.
Select switching type (ref. table below) using keys
6.
Press
OK
i
In order to deactivate settings made, repeat actions from 1 to 4.
Press
OK
to confirm "DEACTIVAT" selection.
Channel
Display
C1
or
C2
Symbol
Selection
(twin channel)
Perm
On
off
temp
timer
on
off
*Set the time as per previous procedure, entering On and Off.
Note: closing of the external input contact is detected immediately by the clock,
while opening can take max 1 sec.
28
.
to confirm.
. (dual channel mod.).
OK
.
to confirm.
External
Function
control
Permanent forcing
of channel ON o OFF.
Switch
Temporary forcing of the
channel until the next
Button
switching of a program set
previously.
Forcing of a timed channel
(e.g. stairway lighting
Button
Control).
*Time may be set in format
Hh:mm:ss.

3-8-4 Maintenance

Allows setting of an operating period in ON for channel C1 and/or C2 (dual channel
mod.). After this period, the clock signals the need for an operation with the writing
"C1 MANUT" or "C2 MANUT", alternating with the current date.
This information can be used to perform maintenance at predetermined intervals of
time on the connected output device.
1.
Select the "MAINTENAN" sub-menu using keys
»
C1 flashes.
m a i n t e n a n
2.
Select channel using keys
.
3.
Press
OK
to confirm.
4.
Set number of hours using keys
c 1
i
Keep the arrow key pressed to
M a i n t e n a n
rapidly increase/decrease the tens, hundreds, etc.
Repeated pressing moves the unit forward one at a
time.
5.
Press
to move on to the next channel
OK
or press
MENU
i
In order to modify or rest the values, follow
Instructions from 1 to 5.
Note:
if you modify the maintenance count setting, you will lose any partial count
that may have already accumulated
.
Cancel maintenance notice
At the end of the countdown, the MAINTENAN message flashes on the active screen.
You can cancel the message once you have completed the necessary maintenance
by pressing
, pressing and holding for about 2 seconds during the active channel
OK
warning.
Attention: when you cancel the MAINTENAN message, the maintenance hour
count restarts automatically.
i
Set the counter to zero for the channel and/or channels to
disable the MAINTENANCE hour count.
.
(twin channel models).
.
.
(dual channel only)
to exit.