Herunterladen Inhalt Inhalt Diese Seite drucken

Ingersoll-Rand QC100 Benutzerhandbuch Seite 5

Vorschau ausblenden Andere Handbücher für QC100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 41
Operation Flowchart Admin Setup for QC100
...ADMIN MENU...
CYCLE TIME
...ADMIN MENU...
CYCLE DELAY
...ADMIN MENU...
PASS SHUTOFF OFF
...ADMIN MENU...
REHIT ON
...ADMIN MENU...
REHIT SHUTOFF OFF
...ADMIN MENU...
PGRM LOCKOUT OFF
...ADMIN MENU...
PSET LOCKOUT OFF
...ADMIN MENU...
ADMIN LOCK OFF
...ADMIN MENU...
TARGET TORQUE
...ADMIN MENU...
BATCH COUNT
...ADMIN MENU...
BATCH TIMER
...ADMIN MENU...
OIL CHANGE CT
...ADMIN MENU...
MAINTENANCE ALARM
45498318_ed1
CYCLE TIME
TIME: 187
CYCLE DELAY
DELAY: 5484
Cycle delay goes from 0 to 6500.
...ADMIN MENU...
PASS SHUTOFF ON
...ADMIN MENU...
REHIT OFF
...ADMIN MENU...
REHIT SHUTOFF ON
...ADMIN MENU...
PGRM LOCKOUT ON
...ADMIN MENU...
PSET LOCKOUT ON
LEARN ADMIN CODE
CODE: ****
SELECT TARGET TQ
TQ: 13.00
SET BATCH COUNT
COUNT: 10
SET BATCH TIMER
TIME: 154
0/115200
UP/CLR DWN/SET
MAINT: 5000
FLOW: 2791 READY
Time taken by Tool to complete tightening from its start. (for
one fastener). Use UP/DOWN arrows to adjust value.
Minimum time gap between two consecutive run downs (100
count = approx 1 sec). Use UP/DOWN arrows to adjust value.
Enables Pass Shutoff.
Select PASS SHUTOFF OFF if you are not using a shutoff valve
or you do not wish to use an installed shutoff valve.
If REHIT OFF is selected. Rehits will not register as an error.
Enable or disable Rehit Shutoff (Switches shutoff valve when
rehit is detected).
Enable or disable access to change program settings.
Enable or disable access to select between two set programs.
Set Password to enter admin menu: select 4 keystroke
combination from four buttons on front panel. Next time
Admin Button is pressed, must enter this code for access.
Enter value that tool has already been set to achieve. This
value is for reference only.
Change the number of fasteners counted per batch using the
UP/DOWN arrow keys between 0-99.
Batch timer goes from 0 to 999 seconds and is a check for
each batches time frame. It is the maximum time between
beginning of the first cycle and end of last cycle.
Goes from 0 -999,999 cycles, measures number of cycles till
next oil change.
Use UP/DWN arrow to adjust the flow reading at which alarm
will sound for maintenance. It is recommended to run down
fasteners at the low torque limit for the application and make
a note of the flow reading. Then adjust the alarm setting to the
average flow reading at the low torque condition.
EN
EN-4

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Qc200

Inhaltsverzeichnis