Fault
The heater has a
fault: the red lamp on
the operating panel
lights up.
GA 42-60-85-110
Cause
8
There is no or not
enough gas pressure for
the magnet valves.
9
The magnet valves do
not open.
10 The ionisation pin is
dirty.
11
The protection gauze in
front of the fan is dirty.
12 The maximum thermo-
stat has been switched
off
40.020.947 - rev. 01 - 2007
Solution
Check if the shut-off valve on
the gas bottle is open.
Check if the gas bottle is
empty.
Press the button of the hose-
breaking protection and the
reset button on the operating
panel.
Press the reset button of the
maximum thermostat and on
the operating panel.
Check the maximum thermo-
stat.
Check the magnet valves.
Check the electrical connec-
tion.
Clean the ionisation pin with
steel wool.
Clean the protection gauze.
Check the suction grate and
the blower outlet for dirt and
for sufficient room for a free
flow.
Press the reset button of the
maximum thermostat and on
the operating panel.
Check if the fan is running
heavily or blocked. Contact
the dealer if necessary.
Check the fan for proper
operation. Replace the fan, if
necessary.
English
Action
User
User
User
User
Dealer
Dealer
Dealer
User
User
User
User
User
Dealer
23