Herunterladen Inhalt Inhalt Diese Seite drucken

Velleman CTC1000DS Bedienungsanleitung Seite 7

Tür-/fensterkontakt für ctc1000
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 36
The magnet must align with the marked side of the door
contact as shown in figure.
o The magnet should not be more than 15 mm from the detector
when the door is closed.
o Ensure the tamper switch spring is positioned so that it makes
contact with the mounting surface through the tamper switch
aperture.
o Windows can be protected similar to door installations. When
fitting to a window fix the magnet to the moving window part
and the door switch to the stationary frame.
5.
Put the control panel into Walk Test mode, and press the test
button on the door contact.
The LED indicator will now flash every time the door contact is
operated.
6.
Fit the white caps to the two mounting holes of the door contact.
7.
Installation is finished.
7.4
Mounting the door/window contact with the extension
terminal
The door contact has an extension terminal providing enhanced
installation flexibility. The extension terminal may be useful for the
following:
 If the door contact cannot be
mounted on the door frame, you
can connect an additional
(extension magnet switch) to
the (Extension Terminal)
mounting the door contact
remotely.
 More than one window and door
can be protected by a door
contact using the additional
magnet and extension magnet
switch. The switches must be
wired to the (Extension Terminal) as shown:
 Any dry contact device with N.C. (normally closed), such as a
broken glass detector, gas detector, water sensor etc, can be
connected to the (extension terminal) making the door contact
serve as an (universal transmitter).
V. 01 – 12/06/2013
CTC1000DS
7
©Velleman nv

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis