PROBLEM
The appliance is pressurised but releases little
steam.
There is a bad smell when turning on suction.
Steam is dispensed mixed with drops of water.
The holder with cloth for steam cleaning does
not lock onto the brush.
Accessories are difficult to assemble.
Steam or condensation leaks out between the
handle and the telescopic tube.
The filling pump of the boiler continues to
operate.
After vacuuming, traces of liquid remain on the
flooring.
ALARMS
Should the problems persist, contact an Authorised Polti Service Centre (see www.polti.com for the up-to-date list) or
Customer Services.
CAUSE
The steam is set to the minimum level.
Dirt collector is dirty or too wet.
The steam hose and/or the telescopic
tube are cold.
The brush is in position B or C.
The seals produce friction.
Seals worn, cut or missing.
There is air in the boiler circuit.
Liquid remains inside the tubes.
Floor not yet dry
- "Out of water" indicator light flashing
- Prolonged beeping sound
- LED programs flashing
- 1st steam adjustment LED flashing
- "Out of water" indicator light flashing
- Prolonged beeping sound
- LED programs flashing
- 2nd steam adjustment LED flashing
- "Out of water" indicator light flashing
- Prolonged beeping sound
- LED programs flashing
- 3rd steam adjustment LED flashing
SOLUTION
Press the steam adjustment button (+) to increase
the steam being dispensed.
Clean the dirt collector as described in Chapter 13
or simply dry it out If the smell persists, carry out a
full clean as described in Chapters 13, 14, and 17.
Direct the steam jet onto a cloth to heat up the
tubes.
Set the universal brush to position A.
Lubricate the gasket
Vaseline, or alternatively with a small amount of
vegetable oil.
Replace the seals, as indicated in Chapter 24.
Turn off the appliance and leave it to cool, then
repeat the operations described in Chapter 1.
Suck in air for a few seconds to allow the transfer of
the liquid to the tank.
Repeat the vacuuming.
CAUSE
SOLUTION
Boiler fault.
Turn the appliance off for a few minutes and
then start it again. Should the problem occur
again, contact an Authorised Service Centre.
The boiler does
Turn the appliance off for a few minutes and
not reach the
then start it again. Should the problem occur
desired
again, contact an Authorised Service Centre.
temperature.
The pump
Turn the appliance off for a few minutes and
continues to take
then start it again. Should the problem occur
in water.
again, contact an Authorised Service Centre.
| 41 |
with silicone grease or