User manual - ENG
Please read in connection with the powered air purifying respirator CleanAIR® AerGO® (hereinafter
PAPR) CleanAir® AerGO® powered air purifying respirator user manual.
When changing the filters always change both filters at the same time.
The CleanAIR® AerGO® Spark arrester (30 00 20) and Prefilter (30 00 15) increases the lifetime of
the CleanAIR® AerGO® filters and it is highly recommended to be used at all times.
CleanAIR® AerGO® Odour filters (30 00 25) reduces unpleasant odour.
Use ONLY approved original filters designed for your CleanAIR® AerGO® unit. Ensure that you use
only brand new and intact filters.
Replace the filters every time you feel a change of smell in the air coming from the unit.
Filters which have exceeded their expiration date must NOT be used! The date is marked on each
filter.
FILTER against particles P R SL for CleanAIR® AerGO®
Product code: 30 00 10/2
As default, the CleanAIR® AerGO® system is equipped with a highly efficient P R SL particle filters and
protect its user against solid and liquid aerosols. These filters, when used with CleanAIR® AerGO® as
part of an approved system, meets the European Standard EN 12941 (detailed classification listed in
CleanAIR® AerGO® user manual). The CleanAIR® AerGO® system must be used with CleanAIR® AerGO®
filters at all time.
Combined filters for CleanAIR® AerGO®
A1 P R SL - Product code: 30 03 57 and A1B1E1 P R SL – Product code: 30 03 64
Combined filters A1 P R SL and A1B1E1 P R SL for CA AerGO® are compatible accessories of personal
air purifying respirator (PAPR) unit CleanAIR® AerGO®.
Except of protection against particles in form of solid and liquid aerosols the protection against organic
gases and vapours with a boiling point above 65°C is provided. The main group of these substances
are hydrocarbons (e.g.: toluene, benzene, xylene, styrene, cyklohexane, trichlorethylene, tetrachlorme-
tane) and organic solvents and thinners (petrol, kerosene, diesel, mineral turpentine, ethylenglycol,
metyl isobutyl ketone, isobuthanol, etc.).
The filter CA AerGO® A1B1E1 P R SL further provides protection against inorganic gases and vapours
(e.g. florine, chlorine, hydrogen sulfide, hydrogen cyanide, hydrogen bromide, hydrogen chloride and
hydrogen peroxide), acid gases and vapours (e.g. carbon dioxide, sulphuric acid, hydrochloric acid,
formic acid, hydrogen fluoride).
Above mentioned filters are compatible accessories of PAPR unit CleanAIR® AerGO® approved in compli-