3. Specifications
3.1 Technical data BERING Inverboost heat pumps
CE Standard, R32, Steel Cabinet
Model
* Performance at Air 28℃, Water 28℃, Humidity 80%
Heating capacity
Power consumption
C.O.P.
* Performance at Air 15℃, Water 26℃, Humidity 70%
Heating capacity
Power consumption
C.O.P.
* Performance at Air 0℃, Water 26℃, Humidity 78%
Heating capacity
Power consumption
C.O.P.
Compressor type
Voltage
Rated current
Minimum fuse
Advised pool volume
Advised water flux
Water pressure drop
Heat exchanger
Water connection
No. of Fan
Fan speed
Power input of Fan
Noise level(10m)
Noise level(1m)
Refrigerant (R32)
CO2 equivalent
Net weight
Gross weight
Net dimension
Packing dimension
BEXP05i
kW
5-3.2
kW
0.98-0.43
7.4-5.1
kW
3.7-2.3
kW
0.93-0.43
5.4-4
kW
2.76-1.7
kW
0.99-0.40
4.2-2.8
V
A
4.40
A
7.00
0-15
m³/h
2.50
Kpa
12
mm
RPM
W
dB(A)
36-42
dB(A)
44-51
g
400
Tonne
0.27
kg
52.00
kg
64.00
mm
mm
BEXP07i
BEXP09i
7-3.3
9-3.5
1.32-0.43
1.61-0.43
7.7-5.3
8.5-5.6
4.7-2.4
6.6-2.5
1.18-0.43
1.65-0.43
5.6-4
5.8-4
3.5-2.0
4.50-2.3
1.25-0.48
1.61-0.55
4.2-2.8
4.2-2.8
MITSUBISHI INVERTER COMPRESSOR
220~240V / 50Hz or 60Hz /1PH
5.90
7.20
9.00
11.00
10-25
15-30
2.50
2.80
12
12
Twist-titanium tube in PVC
650-870
80
37-42
37-43
45-52
45-52
500
650
0.34
0.44
54.00
56.00
66.00
68.00
1049*375*551
1110*430*705
15
BEXP11i
11-4.8
1.96-0.6
8.5-5.6
7.9-3.5
1.98-0.6
5.8-4
5.5-3.0
1.96-0.71
4.2-2.8
8.70
13.00
20-60
3.70
14
50
1
650-850
200
39-45
46-54
750
0.51
68.00
73.00
1086*450*693
1140*495*855
BEXP14i
14-5
2.5-0.63
8.5-5.6
9.5-3.6
2.38-0.62
5.8-4
7-3.2
2.5-0.76
4.2-2.8
11.00
17.00
20-66
4.00
15
40-46
47-56
950
0.64
73.00
78.00