Repair Parts Sheets for this product are available from the Enerpac web site at www.enerpac.com, or from your nearest
Authorized Enerpac Service Center or Enerpac Sales office.
IMPORTANT RECEIVING INFORMATION
CONTENTS
DESCRIPTION
SAFETY INFORMATION
®
10/04
Visually inspect all components for shipping damage. If any shipping damage is found,
notify carrier at once. Shipping damage is not covered by warranty. The carrier is
responsible for all repair or replacement resulting cost resulting from damage in
shipment.
ENGLISH ................1-3
DEUTSCH ...............4-6
These 4-way 3-position manual valves have a float offset flow path in the center
position, which blocks off oil flow from the power source when the valve is in the
neutral position.
The CYL1 and CYL2 valve ports drain to tank in the center position, allowing hoses
from the valve or the manifold to be disconnected from the fixture in double-acting
palletized operations. One of the ports can be blocked off for single-acting applications.
NOTE: Use demand-style power units with these valves to prevent excessive heat build-
up when the valve is in the center position. Pressure switch electric pumps or the Turbo
air pump are demand-style power units that will not run over the relief when oil flow is
deadheaded, preventing heat build-up.
To avoid personal injury or property damage during system operation, read and follow
all CAUTIONS, WARNINGS, and INSTRUCTIONS included with or attached to each
product. ENERPAC CANNOT BE HELD RESPONSIBLE FOR DAMAGE OR
INJURY RESULTING FROM UNSAFE USE OF PRODUCT, LACK OF
MAINTENANCE, OR INCORRECT PRODUCT AND SYSTEM APPLICATION.
Contact Enerpac when in doubt as to applications or safety precautions.
WARNING
To avoid personal injury, always wear proper personal protective gear
when operating hydraulic safety equipment, i.e. safety glasses, gloves, etc.
WARNING
Make sure that system components are protected from external sources of
damage, such as explosive heat, flame, moving machine parts, sharp objects, and
corrosive chemicals. DO NOT expose equipment to temperatures above 150°F
(65°C).
Instruction Sheet
VMMD001, VMMD003, VMMD002,
VMTD001, VMTD003 Manual Valves
FRANÇAIS ....................7-9
ESPAÑOL ..................10-12
ITALIANO...........13-16
NEDERLANDS...17-20
Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Enerpac VMMD001

  • Seite 4: Wichtige Anweisungen Für Die Eingangskontrolle

    L2147 Rev. A 10/04 Das Ersatzteilblatt für dieses Produkt finden Sie auf der Enerpac Website www.enerpac.com, oder bei Ihrem nächstgelegenen authorisierten Enerpac Service Center oder einem Enerpac Vertriebsbüro. WICHTIGE ANWEISUNGEN FÜR DIE EINGANGSKONTROLLE Unterziehen Sie alle Teile einer Sichtkontrolle auf eventuelle Transportschäden. Wird ein solcher Transportschaden festgestellt, benachrichtigen Sie unverzüglich den...
  • Seite 5: Technische Daten

    Konsolenmontage Die Montagehalterung entfernen. Der Durchmesser des Konsolenausschnitts beträgt 3,58 cm bei einer maximalen Plattenstärke von 0,64 cm. Das Ventil kann mit Hilfe der mitgelieferten Gegenmutter sicher in der Konsolenplatte befestigt werden. VMMD001, VMTD002 und VMMD003 4,05 [1.60] 2,16 Diese Ventile auf Einfach- oder Mehrfach-Platz- [.85]...
  • Seite 6: Betrieb

    Rückschlagventil benutzt wird, oder den Stehbolzensatz F107028-3 verwenden. BETRIEB Ventilstellungen Durchfluß zu C1 Neutral Durchfluß zu C2 Rücklauf von Rücklauf von C1 Rücklauf von C1 C2 zum Tank und C2 zum Tank zum Tank VMMD001 VMMD002 VMTD001 VMMD003 VMTD003 Abbildung 5...

Diese Anleitung auch für:

Vmmd002Vmtd001Vmtd003

Inhaltsverzeichnis