English

The hood can look different to that illustrated in the drawings
EN
in this booklet. The instructions for use, maintenance and
installation, however, remain the same.
Closely follow the instructions set out in this manual. All
responsibility, for any eventual inconveniences, damages or fires
caused by not complying with the instructions in this manual, is
declined. The hood is conceived for the suction of cooking fumes
and steam and is destined only for domestic use.
!
It is important to conserve this booklet for consultation at any
moment. In the case of sale, cession or move, make sure it is
together with the product.
!
Read the instructions carefully: there is important information
about installation, use and safety.
!
Do not carry out electrical or mechanical variations on the
product or on the discharge conduits.

GENERAL SAFETY

The minimum distance between the supporting surface for the
cooking equipment on the hob and the lowest part of the range
hood must be not less than 50cm from electric cookers and 65cm
from gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater
distance, this must be adhered to.
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must verify
suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take the
weight of the hood. Do not tile, grout or silicone this appliance
to the wall. Surface mounting only.
WARNING! Do not connect the appliance to the mains until the
installation is fully complete.
Before any cleaning or maintenance operation, disconnect hood
from the mains by removing the plug or disconnecting the mains
electrical supply. Always wear work gloves for all installation and
maintenance operations.
The appliance is not intended for use by children or persons with
impaired physical, sensorial or mental faculties, or if lacking in
experience or knowledge, unless they are under supervision or
have been trained in the use of the appliance by a person
responsible for their safety.
This appliance is designed to be operated by adults, children
should be monitored to ensure that they do not play with the
appliance.
This appliance is designed to be operated by adults. Children
should not be allowed to tamper with the controls or play with the
appliance.
Never use the hood without effectively mounted grating!
The hood must NEVER be used as a support surface unless
specifically indicated.
The premises where the appliance is installed must be sufficiently
ventilated, when the kitchen hood is used together with other gas
combustion devices or other fuels.
The ducting system for this appliance must not be connected to
any existing ventilation system which is being used for any other
purpose such as discharging exhaust fumes from appliances
burning gas or other fuels.
The flaming of foods beneath the hood itself is severely prohibited.
The use of exposed flames is detrimental to the filters and may
cause a fire risk, and must therefore be avoided in all
circumstances.
Any frying must be done with care in order to make sure that the
oil does not overheat and ignite.
Accessible parts of the hood may became hot when used with
cooking appliance.
With regards to the technical and safety measures to be adopted
for fume discharging it is important to closely follow the regulations
provided by the local authorities.
The hood must be regularly cleaned on both the inside and
outside (AT LEAST ONCE A MONTH).
This must be completed in accordance with the maintenance
instructions provided in this manual). Failure to follow the
instructions provided in this user guide regarding the cleaning of
20
the hood and filters will lead to the risk of fires.
Do not use or leave the hood without the lamp correctly mounted
due to the possible risk of electric shocks.
We will not accept any responsibility for any faults, damage or
fires caused to the appliance as a result of the non-observance of
the instructions included in this manual.

ELECTRICAL CONNECTION

The mains power supply must correspond to the rating indicated
on the plate situated inside the hood. If provided with a plug
connect the hood to a socket in compliance with current
regulations and positioned in an accessible area, after installation.
If it not fitted with a plug (direct mains connection) or if the plug is
not located in an accessible area, after installation,
double pole switch in accordance with standards which assures
the complete disconnection of the mains under conditions relating
to over-current category III, in accordance with installation
instructions.
Warning! Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that the
mains cable is correctly assembled.
Replacing the power cable
Warning! Power cable replacement must be undertaken by the
authorised service assistance centre or similar qualified person.

AIR VENT

(for the suction versions)
Connect the hood and discharge holes on the walls with a
diameter equivalent to the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller
dimensions will cause a diminution of the suction performance and
a drastic increase in noise.
Any responsibility in the matter is therefore declined.
!
Use a duct of the minimum indispensible length.
!
Use a duct with as few elbows as possible (maximum elbow
angle: 90°).
!
Avoid drastic changes in the duct cross-section.
!
Use a duct as smooth as possible inside.
!
The duct must be made of certified material.
!
The company declines any responsibility whenever these
regulations are not respected.
FILTERING OR DUCTING ?
!
Your cooker hood is ready to be used in suction version.
To use the hood in filtering version the special ACCESSORY
KIT must be installed.
Check on the first pages of this manual if the ACCESSORY
KIT is furnished or must be bought separately.
Note: If furnished, in certain cases, the additional activated
carbon filtering system may be installed on the hood.
Information about the conversion of the hood from suction
version to filtering version is present in this manual.
Ducting version
In this case the fumes are conveyed outside of the building by
means of a special pipe connected with the connection ring
located on top of the hood.
Attention! The exhausting pipe is not supplied and must be
purchased apart.
Diameter of the exhausting pipe must be equal to that of the
connection ring.
In the horizontal runs the exhausting pipe must be slightly slanted
(about 10°) and directed upwards to vent the air easily from the
room to the outside.
Attention! If the hood is supplied with active charcoal filter, then it
must be removed.
Filter version
One active charcoal filter is needed for this and can be obtained
from your usual retailer.
The filter removes the grease and smells from the extracted air
before sending it back into the room through the upper outlet grid.