RIN-APU24 Uninterruptible Power
Supply
GENERAL
These instructions pertain to the following six scenarios:
wiring the RIN-APU24 to a Power Supply Module XP502,
which in turn is powering XC5010C / XC6010 controllers
(see section "XC5010C / XC6010" and its three sub-
sections);
wiring the RIN-APU24 to an XCL5010 controller (see
section "XCL5010" on page 2);
wiring the RIN-APU24 to an XL100C controller (see
section "XL100C" on page 2);
wiring the RIN-APU24 to a FALCON controller (see
section "FALCON" on page 2); and
wiring the RIN-APU24 to a LION controller (see section
"LION" on page 2).
wiring of the RIN-APU24 to an EAGLE controller (see
section "EAGLE" on page 3).
XC5010C / XC6010
The following pertains to the wiring of the RIN-APU24 to a
Power Supply Module XP502 powering XC5010C / XC6010
controllers.
Using external cables, wire RIN-APU24 to terminals 1, 2, 7,
and 8 of the XP502. In case of the reversed connection of
terminals 1 and 2 (+, -), the yellow LED will remain lit con-
stantly. The yellow LED can then be activated only if terminals
7 and 8 are wired to the RIN-APU24.
CAUTION
Do not use the switch contacts 4, 5, and 6 of the
RIN-APU24 in parallel with other devices.
Special Case 1
Fig. 1 pertains to the wiring of the RIN-APU24 to an XP502
powering XC5010C / XC6010 controllers equipped with
internal modules, but not connected to Distributed I/O's.
NOTE:
When LED (L3) is lit, this indicates that the
XC5010C / XC6010 controllers are running on
battery power.
NOTE:
The output of the RIN-APU24 must not be
connected with any other devices.
Copyright © 2012 Honeywell GmbH ● All Rights Reserved
Mounting Instructions
UNINTERRUPTABLE POWER SUPPLY
RIN-APU24-2
1 L
AC
1.6 A
230V~
(+6%/-10%)
50...60 Hz
DC
2 N
3 PE
SWITCHED POWER
SUPPLY
WATCHDOG
max.
24 V~
3 A
Fig. 1. XC5010C / XC6010 with internal modules
Special Case 2
Fig. 2 pertains to the wiring of the RIN-APU24 to an XP502
powering XC5010C controllers connected with Distributed
I/O modules, but not equipped with internal modules.
NOTE:
In the case of the XC5010C, there must be no
connection between its GND and the GND of the
Distributed I/O modules.
Relay K1 ensures that the power supply of the Distributed I/O
modules will be switched OFF whenever the XP502 is
switched OFF.
RIN-APU24-2
1 L
AC
1.6 A
230V~
(+6%/-10%)
50...60 Hz
DC
2 N
3 PE
SWITCHED POWER
SUPPLY
C4
OF THE SAME CONTROLLER
Fig. 2. XC5010C with Distributed I/O modules
RIN-APU24
MOUNTING INSTRUCTIONS
XP502
8, 9
1
4 A
24 Vdc
2
10, 11
4 A
3
BATTERY
4
BATTERY
5
OPERATION
6
C4
NC6
NO5
7
8
16
17
18
8, 9
4 A
24 Vdc
10, 11
4 A
BATTERY
BATTERY
OPERATION
NC6
NO5
TO OTHER XSL511s
MU1Z-0977GE51 R1112
K1
XP502
1
2
3
4
5
6
7
8
16
17
K1
18
XSL511
1
2
3
4
5
6
24V
~