Herunterladen Inhalt Inhalt Diese Seite drucken

Küppersbusch EKI9954.1F Bedienungsanweisung Mit Montageanweisungen Seite 58

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connection of the hob
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
st
Put the 1
bridge between terminal 1 and 2, the 2
between 4 and 5.
Attach the earth to the terminate "earth", the neutral N to terminal 4 or 5, the Phase L to one of
the terminals 1,2 or 3.
Biphase
400V~2P+N
st
Put the 1
bridge between terminal 1 and 2, the 2
Attach the earth to the terminate "earth", the neutral N to terminal 4 or 5, the Phase L1 to the
terminals 1or 2 and the Phase L2 to the terminal 3.
Triphase
400V~3P+N
Put a bridge between terminal 4 and 5.
Attach the earth to the terminate "earth", the neutral N to terminal 4 or 5, the Phase L1 to the
terminals 1, the Phase L2 to the terminal 2.and the Phase L3 to the terminal 3.
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.
nd
between terminal 2 and 3 and the 3
nd
between terminal 4 and 5
58
rd

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis