MC 40-1: Changing the stripping blade
2
Left blade
•
3
4
•
•
•
Right blade
•
•
•
•
•
MC 40-1
MC 40L: Changing the stripping blade
•
•
•
MC 40L
•
•
WARNING: Risk of injury!
The stripping blades are sharp. Be careful not to injure
yourself.
Unscrew the Allen screw (1) and take out the old blade (2).
Put new blade on the pin (3).
Fix the limit plate (4).
Tighten the Allen screw (1).
Unscrew the Allen screw (1) and take out the old blade (2).
Fix new blade.
Loosen the Allen screw (5).
Attach tappet over the groove (6) at the correct incision depth
(0 = initial position).
Press the blade against the tappet and tighten both Allen
screws (1) and (5).
WARNING: Risk of injury!
The stripping blades are sharp. Be careful not to injure
yourself.
Unscrew the Allen screw (1) and take out the old blade (2).
Attach the new blade to the guiding pin (3).
Adjust the incision depth of the stripping blade to the conductor
to be processed.
Adjusting the blade changes the incision depth by ±0.25 mm.
Tighten Allen screw (1).
Check incision depth by stripping a conductor. The copper
strands must not be cut by the stripping blade.
Maintenance
13