Timer mode
=> Set timers
On at
00:00
Off at 00:00
Set the desired switching times. Depending on the
selected time clock the on/off times are displayed with
+ / – (24 hour) or arrows (asymmetric timer).
Press the PTK to return to the main screen.

5.4 Set startup delay

You are in the main menu. Select "Startup delay".
Set timers
=> Startup delay
Startup delay:
.. minutes
Adjust the amount of minutes (up to 300 minutes) and
press the PTK or wait a few seconds to return to the
main screen.

5.5 Temperature settings

On the Ballast Connect Micro you can set the "normal"
and "overheat" temperature, provided that a Temp
Probe (not supplied) is connected to the Ballast
Connect Micro.
ATTENTION: Before connecting the Temp Probe you
must first switch off the Ballast Connect Micro via
the "maintenance mode" (see section 5.8). Then
disconnect the Ballast Connect Micro from the
socket. Plug the Temp Probe into the Ballast
Connect Micro and reconnect the Ballast Connect
Micro to the socket.
You are in the main menu. Select "Temperature".
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
Startup delay
=> Temperature
Set the values for "normal" en "overheat".
Normal °C
28.0
Overheat
32.0
Press the PTK to return to the main screen.
A notification is displayed during an over-temperature
situation.
34.2 °C
10:57:28
O
Overheat!
At "Overheat T" one lamp will be turned off. The red
LED goes off. This can be a random lamp, but there is
also the option to always switch off relay L2. In this case
L1 (lamp 1) remains switched on, even during an over-
temperature situation.
To adjust L1 to remain switched on, select "Keep lamp
On" in the main menu under "Settings".

LCD on-time

200s
=> Keep lamp
On
As soon as the temperature falls under "Normal temp"
the lamp will be turned on again.
No lamp will be switched between "Normal temp" and
"Overheat T".
5.6 LCD on-time
You are in the main menu. Select "Settings" and then
"LCD on-time".
=> LCD on-time
200s
Keep lamp
On
Select the desired number of seconds and confirm by
pressing the DDK.