Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications; Temperature Range - Buffalo CW147 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
Troubleshooting
Fault
Indicator Light does
The unit is not switched on
not come on & unit
does not heat up
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Thermostat has failed
Indicator Light
Heating element has failed
comes on but unit
Thermostat has failed
does not heat up
Loud noises
The appliance has not been installed
in a level or stable position
The appliance is too close to a wall
or other object
Odour from the unit Unit is not cleaned for long time

Technical Specifications

Model
Voltage
CW147
220-240V
50Hz
CW148
220-240V
50Hz
CW147-CW148_ML_A5_v2_20181205.indb 5
Probable Cause
Temperature
Power
Current
range
500W
2.2A
30°C ~ 90°C
800W
3.5A
30°C ~ 90°C
Solution
Check the unit is plugged in correctly and
switched on
Call BUFFALO agent or qualified Technician
Replace the plug fuse
Check power supply
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Check installation position and change if
necessary
Move to a well-ventilated position.
Clean the unit thoroughly
Dimensions
Capacity
h x w x d mm
46L
420 x 773 x 336
68L
420 x 1127 x 336
UK
Weight
15kg
22kg
5
2018/12/5 17:17

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cw148

Inhaltsverzeichnis