Maximum cutting performance in aluminum
Maximum cutting performance in unalloyed steel
Cutting angle (left/right)
Suction adapter outside diameter
4.2
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the total
working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise emission values
Sound power level (L
WA
Uncertainty for the sound power level (K
Sound pressure level (L
Uncertainty for the sound pressure level (K
Total vibration
Vibration emission value for sawing wood sheets (a
Vibration emission value for sawing sheet metal (a
Uncertainty (K)
5
Use of extension cords
WARNING
A damaged supply cord presents a hazard! Do not touch the supply cord or extension cord if damaged
while working. Disconnect the supply cord plug from the power outlet.
▶ Check the appliance's supply cord at regular intervals and have it replaced by a qualified specialist if
found to be damaged.
Use only extension cords of a type approved for the application and with conductors of adequate
cross-section. Otherwise the performance of the appliance may be affected and the cord may overheat.
Regularly check the extension cord for damage.
Replace damaged extension cords.
When working outdoors, use only extension cords that are approved and correspondingly marked for
this application.
Recommended minimum conductor gauge (cross section) and maximum cable length with 120V
supply voltage
Extension cables
Extension cable conductor gauge
Extension cable conductor gauge
Extension cable length
Extension cable length
*2150159*
Printed: 27.06.2019 | Doc-Nr: PUB / 5500677 / 000 / 00
)
)
WA
)
pA
)
pA
AWG 16
1,31 mm²
2,58 kcmil
25 m
75 ft
2150159
)
h,B
)
h,M
AWG 14
AWG 12
2,08 mm²
3,31 mm²
4,11 kcmil
6,53 kcmil
30 m
50 m
100 ft
150 ft
SJT 6
25 mm
10 mm
0°, 15°, 30°, 45°
27.5 mm
SJT 6
98 dB(A)
5 dB(A)
87 dB(A)
5 dB(A)
SJT 6
5.8 m/s²
5.6 m/s²
1.5 m/s²
AWG 10
5,26 mm²
10,4 kcmil
100 m
250 ft