At startup the lamp also shows the ID and radio channel used (see
above).
Alarm SMS / Status SMS
When you receive an Alarm SMS or when you have requested a Status
SMS it will contain all or some of the information below:
Example
*Ontech9035
Ver 34
Alarm:
2ab
2/extTemp
Inputs:
2a
Units:
1/224/25.1
2*/24/--
4/22/23.8
Thermostat:
1/26
Explanation
Asterisk (*) means alarm function is activated. Ver. indicates
software version
Indicates all alarms that have been activated since the last
acknowledge. The number indicates the units ID number,
The master unit is always no 1, and the others refer to the
extra units or wireless alarm detectors connected.
Note that these inputs cannot send an alarm before the
alarm has been acknowledged.
Indicates a temperature alarm unit with ID2 and external
temperature sensor.
Indicates the alarm input that still is activated. In this
example the SMS means that inputs 2a and 2b has been
activated since the last acknowledge and that input 1a is
still activated.
Indicates the units communicating with master unit .
Master unit ID 1 is always. The other numbers refers to the
extra units connected. An asterisk (*) after the number in-
dicates that the relay is turned on. A number after the slash
indicates the temperature from internal sensor and external
sensor (if there is any).
If the master unit loose contact with one of the extra relays
unit its ID number will not be shown in the SMS after one
hour.
Indicates the set temperature for the thermostat function.
If thermostat is not activated there is no information on
the row.
- 12 -