4.1 Installation

Isotherm refrigerators have been designed and constructed exclusively for recessed
installation and installation that is in compliance with standard dimensions. The
refrigerator must always be in a horizontal position, with the compressor's rubber
feet at the bottom. The compressor is capable of functioning at angles of up to
30°. The compressor unit may become damaged if the angle is higher. Also remote
operation compressors must be installed with its rubber feet downward.
Inox drawer refrigerators and freezers with stainless steel and Glass door are
equipped with a three or four side mounting flange for flush installation of the
furniture (except model DR105).
The INOX models come equipped with a stainless steel door, without
replaceable panels.
GLASS models are equipped with a front, coloured glass panel which
can be replaced with various colours (Optional).
When it is not possible to use the mounting flange, secure the refrigerator in such
a way so that it will not tip/slide forward when the drawer is opened or in the case
of sudden vehicle movement. The unit should be anchored by at least 2 fastening
points, in accordance with the provisions of the EN 60335-2-24 standard.