TEMPERATURE
1. Insert the K-type thermocouple into the VΩ
jacks (observe polarity markings on the thermocouple and
meter), and rotate the Function selector switch
Temperature
NOTE: The meter will default to the Fahrenheit scale in this mode.
To enter the Celsius scale, press the 'SELECT' button
that the appropriate icon (either °F or °C ) appears on the display.
2. To measure the temperature, make contact between the
thermocouple tip and the object being measured. When the
thermocouple tip and object are in thermal equilibrium, the
measurement on the display will stabilise. The meter will auto-range
to display the measurement in the most appropriate range.
Remove the thermocouple before switching the meter
to other measurement functions.
The thermocouple included with the original purchase
is suitable for temperatures below 446°F/230°C only. To
measure higher temperatures, a K-type thermocouple
with the appropriate measurement range should be used.
OPERATING INSTRUCTIONS
setting.
K-type
Thermocouple
and COM
5
4
to the
2
once. Ensure
12
11