7
Turn the iron plate's temperature regulating knob (6) to the position "cotton °°°"
(indicated on the iron knob).
8
Wait that the boiler button's red light (4) goes off (it takes about 10 minutes).
While ironing, the boiler button's red light (4) normally comes on.
9
The machine is ready for use.
10
Push the steam button (7).
11
In case the steam stops during ironing and the low water light indicator (5)
comes on, it means that there is not enough water in the tank. To start ironing
again, switch off the boiler button (4); press the steam iron button (7) to ensure
there is no more steam in the boiler, slowly open the pressure cap (1), discon-
nect the plug and refill to the required level. Fill the boiler with warm water and
wait for it to build up pressure again.
12
When you first press the steam button (after having turned the boiler on and
depressed the steam button on the iron) you might notice a decrease in pres-
sure. This is because the tank has air in it. In order to have plenty of steam
(after you have depressed the iron) wait until the pressure goes back up to the
maximum level before you begin.
CAUTION
Do not leave the machine unattended while the plug is connected to the socket.
The iron reaches very high temperatures and it keeps being very hot even 15
minutes after it's been switching off. Be careful not to burn yourself.
For complete safety, before filling the boiler, please disconnect the plug.
While using the machine and 15 afterwards the iron plate has very dangerous
temperature – do not touch it.
While using the machine, never unscrew or remove the cap while under pres-
sure (1). Before removing it, make sure that it does not give off steam anymore
by shutting the boiler off, and pressing the steam iron button (7) to release all
remaining steam.
The machine has a special heating element. Only qualified technician should
replace it.
The safety cap (1) must be replaced with original parts only.
PLEASE NOTE
The use of normal tap water is recommended. In order to clean the boiler and remo-
ve limestone, rinse it internally (every 15-20 litres of water used or every month) with
tap water.

TECHNICAL DATA

Adjustable iron thermostat set from 60°C to 215°C
Bimetallic safety iron thermostat with manual reset at 275°C
Heating element:800W (Version 230V: 50Hz / Version 120V: 60Hz)
Boiler power : 1000W
Working pressure: 2,5 bar
Max. pressure: 5,5 bar
Tank nominal capacity: 1,4 litres
(Version 230V: 50Hz / Version 120V: 60Hz)