Initial operation

Use the pressure adjusting screw (K) of the
system pressure gauge (P) to set the system
pressure to 0.5 bar (7.25 psi) (on TUNZE pH
Controller Set 7074/2). Turning the screw in
will increase the pressure at the gas outlet (O),
whereas turning the screw out will reduce it.
For safety reasons, the pressure adjusting
screw (K) can only be used to set a system
pressure of up to a maximum of 2 bar (29 psi).
Only in case of a defect, the safety valve (R )
will automatically drain the pressure at 3.3 bar
(47.8 psi).
Depending on the temperature, the cylinder
pressure of a full cylinder is normally about 50
bar (725 psi).
Use the CO2 controller to activate the system,
and check the inflow of the CO2 into the
aquarium. Set the required flow intensity by
turning in the fine adjustment valve (L).

Mise en service

A l'aide la vis (K) du réducteur de pression (P),
ajustez la pression d'utilisation de l'installation
à 0,5 bar (par exemple, lors de l'utilisation du
contrôleur TUNZE 7074/2). En tournant la vis
dans le sens horaire, la pression d'utilisation
en (O) augmente. En tournant dans le sens
anti-horaire, la pression diminue.
Par raison de sécurité, la pression d'utilisation
en (K) se règle à maximum 2 bars. En cas
de défaut, la soupape de sécurité (R) se
déclenche automatiquement vers 3,3 bars.
La pression interne normale d'une bouteille
CO2 est de 50 bars en fonction de la
température ambiante.
Nous conseillons le pilotage de l'installation
par un contrôleur CO2.
Le débit de CO2 (nombre de bulles) s'ajuste
par le robinet de réglage fin en partie
inférieure (L).