Indicator lights on the control panel
Red
Green
Condition
LED
LED
Bootloader active (alternately fl ashing)
Ready (for work, activate En_HW)
Work in progress
Warning
Fault
Identifi cation of the motor data
Initializing
Firmware-Update
Bus-fault operation
Bus-fault operational
Table 1: LED fl ash code
Elektror basic parameters
PC-parameter
HMI-parameter
Hint: HMI main menu (HP) submenu
1.020
HP 02. 01. basic parameter (xp.)
1.021
HP 02. 01. basic parameter (xp.)
1.050
HP 02. 01. basic parameter (st.)
1.051
HP 02. 01. basic parameter (st.)
1.100
HP 02. 01. basic parameter (xp.)
1.130
HP 02. 01. basic parameter (xp.)
1.131
HP 02. 01. basic parameter (xp.)
1.132
HP 02. 01. basic parameter (xp.)
1.150
HP 02. 01. basic parameter (xp.)
33.031
HP 02. 07. motor parameter (st.)
33.032
HP 02. 07. motor parameter (st.)
33.034
HP 02. 07. motor parameter (st.)
33.035
HP 02. 07. motor parameter (st.)
33.050
HP 02. 07. motor parameter (st.)
33.105
HP 02. 07. motor parameter (st.)
33.110
HP 02. 07. motor parameter (st.)
33.111
HP 02. 07. motor parameter (st.)
33.138
HP 02. 07. motor parameter (xp.)
34.020
HP 02. 08. control.param. (xp.)
34.021
HP 02. 08. control.param. (xp.)
34.030
HP 02. 08. control.param. (st.)
34.090
HP 02. 08. control.param. (st.)
34.091
HP 02. 08. control.param. (st.)
34.110
HP 02. 08. control.param. (xp.)
(st.) Standard value, always visible
(xp) only in expert mode visible
After each reset and a subsequent re-parameterization the error called „48: motor nameplate data" must be acknowledged.
Subsequently, a motor identifi cation run via the HMI or the software must be started.
Following a successful motor identifi cation run the device is fully confi gured and ready for use.
Quick Start-up of Kostal Inveor Frequency Converter
Description
Low speed
High speed
Deceleration 1
Acceleration 1
Control mode
Ref. channel
Enable software
Start protect
Rot. direction
Motor current
Motor power
Motor speed
Motor frequency
Stator resist.
Leakage induct.
Motor voltage
Lotor cosφ
Hold. curr. time
Flying restart
Fly. restart time
Switch. frequency
Speed control Kp
Speed control Tn
Slip trimmer
Legend
LED out
LED on
LED fl ashes
LED fl ashes fast
Proposed parameter
0Hz
have a look at the type plate
20s ( for larger items more )
10s ( for larger items more )
0 ( frequency control mode)
0 ( internal potentiometer)
0 ( digital input 1)
0 ( inactive)
1 ( only clockwise)
have a look at the type plate
have a look at the type plate
( input in W)
have a look at the type plate
have a look at the type plate
by ID run
by ID run
have a look at the type plate
have a look at the type plate
1 s
1 ( active)
by ID run
2 ( 8kHz)
by ID run
by ID run
0 ( inactive)