CONTENTS
Introduction ............................................................................................................................................................. 2
Packaging Contents ............................................................................................................................................... 2
Solar Transmitter ................................................................................................................................................. 2
Temperature & Humidity Sensor .......................................................................................................................... 2
Overview .................................................................................................................................................................. 2
Transmitter Box ................................................................................................................................................... 2
Temperature & Humidity Sensor .......................................................................................................................... 3
Sensor Installation .................................................................................................................................................. 3
Setup Transmitter Box ......................................................................................................................................... 3
Setup Thermo & Hygro Sensor ............................................................................................................................ 4
Cable Connections ............................................................................................................................................... 5
Transmitter Box-Battery Installation ..................................................................................................................... 5
Channel Setting ................................................................................................................................................... 5
Remove Setting ................................................................................................................................................... 6
LED Light Indicator .............................................................................................................................................. 6
Reset ........................................................................................................................................................................ 6
Maintainance ........................................................................................................................................................... 6
To Maintain the Thermo/Hygro Sensor ............................................................................................................... 6
Trouble Shooting .................................................................................................................................................. 7
Precautions ........................................................................................................................................................... 7
Specifications ....................................................................................................................................................... 7
Outdoor Temperature / Humidity Unit Relative Temperature ............................................................................... 7
Relative Humidity ............................................................................................................................................... 7
Solar RF Transmitter Box .................................................................................................................................... 7
About Oregon Scientific ....................................................................................................................................... 8
EU-Declaration of Conformity .............................................................................................................................. 8
FCC Statement ...................................................................................................................................................... 8
Temperature & Humidity Sensor
Model: THGN301/THGN301A
USER MANUAL
1
loading

Inhaltszusammenfassung für Oregon Scientific THGN301

  • Seite 11 Temperatur & Feuchtigkeits-Sensor Modell: THGN301/THGN301A BETRIEBSANLEITUNG INHALT Einleitung ................................2 Die Verpackung Enthält ............................. 2 Solar-transmitter ..............................2 Temperatur & Feuchtigkeits-sensor........................2 Übersicht ................................. 2 Transmitter-boxe ................................ 2 Temperatur- Und Feuchtigkeitssensor ........................3 Sensor-installation ............................. 3 Montage Der Transmitterboxe ............................ 3 Installation Der Thermo- &...
  • Seite 12: Einleitung

    EINLEITUNG Besten Dank, dass Sie den Oregon Scientific Temperatur- & Feuchtigkeitssensor (THGN301) ausgewählt haben. Dieser Messgeber ist mit dem ultragenauen professionellen Wettersystem (WMR300 / WMR300A) kompatibel. HINWEIS Bitte halten Sie diese Betriebsanleitung 1 x Metall-Befestigungsplatte beim Einsatz Ihres neuen Produkts griffbereit. Sie enthält praktische Schritt-für-Schritt Anweisungen, wie auch...
  • Seite 13: Temperatur- Und Temperatur- Und Feuchtigkeitssensor

    Für die richtige Installation Ihres Sensors benötigen Sie einige Werkzeuge – einschließlich verschiedene Schraubenzieher, Schraubenschlüssel und ein elektrisches Bohrgerät. Die eigentlichen Bedürnisse hängen davon ab, auf welche Weise Sie Ihren Sensor installieren. Die Transmitterboxe ist in der Lage, Daten drahtlos RESET SOLAR RAIN...
  • Seite 14: Installation Der Thermo- & Hygro-Sensoren

    1. Stellen Sie eine Stange, eine Befestigungsplatte aus HINWEIS Vergewissern Sie sich, dass der eingravierte Plastik und eine U-Bolzen ohne Beilagscheiben, Pfeil UP (oben) richtig positioniert ist. Federscheiben und Sechskantmuttern 3. Schieben Sie die verlängerten Tabs der (Schaubild 1) bereit. Befestigungsplatte in die dafür vorgesehenen 2.
  • Seite 15: Kabelverbindung

    2. Montieren Sie die Metallbefestigungsplatte zum HINWEIS Überschüssige Kabellänge nötigenfalls U-Bolzen gesichert durch die 4 Paare der entsprechend sauber führen. Beilagscheiben, Federscheiben und den INSTALLATION DER Sechskantmuttern (Schaubild 9). TRANSMITTERBOX-BATTERIE 3. Platzieren Sie die Stange gesichert in den gewünschten Außenbereich. Das Solarpanel an der Transmitterboxe ist eine Einrichtung, welche Energie spart und so gestaltet, Alternative 2: Sensormontage an einem Holzbrett...
  • Seite 16: Kanaalinstelling

    8 Sätzen an Thermometer- RESET loslassen. Ein rotes Licht wird fünfmal und Feuchtigkeitssensoren aufleuchten. Darauf den SCHLÜSSEL-Knopf ebenfalls (THGN301), erweitert werden loslassen. Die Einstellung der Kanäle und kalibrierte sowie je einem Wind- und Windrichtung wird dadurch vollständig aus der Regensensor (WGR300 oder PCR300), wobei alle Transmitterboxe entfernt.
  • Seite 17: Unterhalt Des Thermo/Hygro-Sensors

    Elektrische Gewitter können gelegentlich einen Problem Symptom Abhilfe Stromstoß verursachen, der elektronische Geräte Transmitter- LED Licht(er) 1. Schalter beschädigt. Zu Ihrer eigenen Sicherheit empfehlen Boxe blitzt/en nicht überprüfen. wir, bei der Benutzung der Haupteinheit oder bei 2. Polarität der Unterhaltsarbeiten während Gewittern Vorsicht walten aufladbaren zu lassen.
  • Seite 18: Ttechnische Daten

    Version maßgebend. EU-KONFORMITÄTSERKLÄRUNG RELATIVE LUFTFEUCHTIGKEIT Hiermit erklärt Oregon Scientific, dass die Anzeigebereich 0% bis 99%RH Temperatuur- & Vochtigheidssensor (Modell: THGN301/THGN301A) oder mit den grundlegenden Betriebsbereich 0% bis 99%RH Anforderungen und anderen relevanten Vorschriften Auflösung der Richtlinie 1999/5/EG übereinstimmt. Eine Kopie Genauigkeit der unterschriebenen und mit Datum versehenen Konformitätserklärung erhalten Sie auf Anfrage über...

Diese Anleitung auch für:

Thgn301a