ELMON relay 42-622
Safety Relay
Signal relay
Max switching current
Mechanical service life
Operating mode RL: Switch-on delay
Operating mode RL: Switch-on duration
Terminating resistor – sensor
Nominal value
Upper switching value
Lower switching value
Certifications
Overall system
(Sensors + Electronics +
Electromechanics)
ELMON relay 42-622
Electronics
Electromechanics
output switching device (Relais)
(SENTIR mat)
Sensor
2 A (230 V AC / 30 V DC)
> 10
operations
6
0,5 sec.
3 sec
R
Nom
R
AO
R
AU
EN ISO 13849-1:2015 Category 3 PL d
(MTTFD 80 years, DC 95 %)
EN 62061:2015 SILCL 2
(PFHd 6,40E-07 1/h)
EN ISO 13849-1:2015 Category 3 PL e
MTTFD 545 years, DC 99 %
B10D 2.000.000
MTTFD 190 years, DC 99 % (Nop 52.560)
B10D 2.000.000
MTTFD 190 years, DC 90 % (Nop 52.560)
= 8,2 kΩ
> 12,0 kΩ
< 5,0 kΩ