Connecting to the Central Unit
Strain-relieve the connection cable for sabotage monitoring and siren/flashing light
power supply through the wall hole from the back of the enclosure into the rear side.
The sabotage opening monitoring contact and the pull-off detector are connected in
series and should be wired up with the sabotage line of the radio alarm central unit.
Terminal Strip
Blitz-
Aussen-
licht
sirene
9
8
7
6
+ -
+
-
Shutting the Enclosure
After a function test of the siren and the flashing light has been made (test alarm at
the radio alarm central unit), the enclosure should be shut by sliding in forward and
then upward.
The enclosure front with the central fixing screw being slightly inclined on the middle
brace. Now, shut the enclosure.
Note: Ensure proper seating of the lateral borders.

Specifications

Operating voltage:
Current consumption,
flashing light:
siren:
Power,
flashing light:
siren:
Alarm duration,
flashing light:
siren:
Ambient temperature:
Protective system:
Dimensions (W x H x D):
Weight:
Connection line:
Sabotage contact:
Material:
Finish:
5
Abreiss-
Deckel-
leine
kontakt
12 kOhm
5
4
3
2
1
Sabotage
12 V DC (9 - 13,8 V DC)
300 mA (at 12 VDC)
300 mA (at 12 VDC)
6.7 Ws (at 1x/sec.)
Approx. 108 dBA (1m / 20 °C / 13.8 VDC)
Until reset
Until unarmed, max. 3 min.
-20°C - +50°C
IP 64
180 mm x 390 mm x 140 mm
2.8 kg
IY ( St ) Y 4 x 2 x 0.6
Normally closed
V2A special stainless steel
Powder-coated, white
Sabotage:
Terminals 1 to 5
Siren:
Terminals 6 and 7
Flashing Light: Terminals 8 and 9