English
Before starting to install and work with this device, please read the Safety
Instructions.
EC Declaration of Conformity
Siemens Security Products hereby declares that this product is in compliance
with the essential requirements and other relevant provisions of Directive
1999/5/EC on Radio and Telecommunications Terminal Equipment (R&TTE)
and 2004/108/EC on Electromagnetic Compatibility (EMC).
The EC Declaration of Conformity is available from your Siemens sales office
or:
Siemens AB, Security Products
Englundavägen 7
SE-171 24 Solna
Sweden
Introduction to the IPAW8-10 Wireless Personal Alarm
The IPAW8-10 Wireless Personal Alarm (WPA) is a belt clip panic device
with three configurable buttons.
Enrollment and testing
To enrol the WPA into the control panel, follow the instructions of the
corresponding installation/configuration manual.
The WPA is supplied with the battery and when installed, the unit is ready to
be enrolled.
Press a key on the WPA to verify that the transmit LED lights.
Make sure that the control panel responds as programmed and as
stated in the installation/configuration manual.
Repeat the test at locations where the WPA will be operated under
normal use, in order to ensure the wireless transmission is not blocked
by any walls or large objects, or affected by structural materials.
Functions (Fig. 1)
No. Key/Indicator. Description
Programmable transmission button which can be
configured to be used solely or in combination with the
Left Button
other buttons to activate an assigned function; (e.g.
1
panic, holdup, suspicion, trigger).
Green
When used in combination they must be pressed
simultaneously for 2 seconds to activate the function
Programmable transmission button similar to green
Top Button
2
button. Activates an assigned function
Yellow
(e.g. panic, holdup, suspicion, and trigger).
You can clip this to a belt or remove to attach under a
3
Belt Clip
desk. Also reversible.
Transmission
4
Lights up for button presses when transmitting.
LED Indicator
Programmable transmission button similar to green
Right Button
5
button. Activates an assigned function
Red
(e.g. panic, holdup, suspicion, and trigger).
All messages include battery state (normal or low). The
6
3.6v Battery
panel raises an alert if the battery power is low.
Reversible Belt Clip (optional, fig. 2, 3, 5, 6)
The belt clip can be fitted in the normal position or upside down, according to
individual preferences. To reverse the position of the clip, remove the screw
holding the belt clip, lift the tab under the clip, slide the clip down, reverse the
position and reattach the screw.
Supervision signaling (Fig 2-6)
The WPA may be configured to send periodic supervision signals.
To enable this feature on the WPA:
Remove the belt clip to provide access to the battery. (See section on
Battery Exchange).
Using a tweezers, insert a jumper onto the two pins located beside the
battery (fig 4, JP2).
Replace the belt clip.
Note: To operate supervision for each WPA, this function also needs to be
enabled on the panel. For configuration instructions, please refer to the SPC
Configuration Manual. If the panel does not get a supervision signal, an alarm is
raised that is displayed on the keypad and logged.
If supervision is not enabled, the WPA sends out a supervision message about
every 24 hours to transmit the WPA battery status to the panel.
Battery exchange (Fig. 2-6)
In order to change the battery, remove the screw holding the belt clip, lift the tab
under the clip, and slide the clip down to have access to the battery holder.
Cautiously remove the old battery and replace it with a new one and close the
housing again. In figure 5 and 6, the belt clip is closed in the reverse position.
Insert the battery in the battery holder making sure the polarity is correct
(+)(-)
Risk of explosion if battery is replaced by an incorrect type.
Clean the WPA only with a soft cloth or sponge moistened lightly with a
mixture of water and mild detergent and wipe it dry immediately. Also never
use solvents such as kerosene, acetone or thinner. The use of abrasives of
any kind is not recommended.
Technical data
Frequency
868 MHz
Range
Max. 150m in open space
Unique ID serial number – 24 bit
Identification
Operating current
Max. 16 mA
Max. 1.3 μA
Quiescent current
Low voltage trigger
Low battery indication below 3.0V
Battery type
Battery Lithium 3.6 V, size 1/2AA, 1 Ah
(type Tadiram TL5902)
Operating temperature
-10 ~ +50
Colour
Black
Weight
0.100 kg (including belt clip and battery)
Dimensions (W x H x D)
115mm x 55mm x 35mm (including belt clip)
Housing
Polycarbonate with reversible belt clip
IP Rating
IP30
RF Module
V5.0