Herunterladen Inhalt Inhalt Diese Seite drucken

User Information; Warranty Information; Installation - Siko Sg5 Benutzerinformation

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

User Information

SG5
Wire Actuated
ENGLISH

1. Warranty information

In order to carry out installation correctly, we
strongly recommend this document is read very
carefully. This will ensure your own safety and
the operating reliability of the device.
Your device has been quality controlled, tested
and is ready for use. Please observe all warnings
and information which are marked either directly
on the device or specified in this document.
Warranty can only be claimed for components
supplied by SIKO GmbH. If the system is used
together with other products, there is no warranty
for the complete system.
Repairs should be carried out only at our works.
If any information is missing or unclear, please
contact the SIKO sales staff.
2. Identification
Please check the particular type of unit and type
number from the identification plate. Type number
and the corresponding version are indicated in the
delivery documentation.
e.g.
SG5-0023

3. Installation

For mounting, the degree of protection specified
must be observed. If necessary, protect the unit
SG5
Datum 25.08.2010
version number
type of unit
against environmental influences such as sprayed
water, dust, knocks, extreme temperatures.
The wire actuated transmitter is a high quality
measuring device and should be mounted to a flat
surface (fig. 1).
Two M3 threads on the lower surface (max. screw-in
depth 6mm) serve to fasten the encoder.
Fig. 1: Mounting
After mounting, check that the maximum exten-
sion length complies with the application (fig.
2). The cable lug or rope must be drawn out to
the intended fastening position. The rope must
not be twisted.
max. extension length
Measuring range
Cable lug
Fig. 2: Extension length check
Attention! Do not extend the wire beyond the
max. allowable extension length and do not twist
wire insert.
Wire handling
Pull out the wire perpendicular to the wire outlet
(fig. 2).
Do not let the wire go; in every position and du-
ring every move the wire must be stretched by the
cable drum's spring force.
For correction function the wire must remain wit-
hout kinks or flattening.
No warranty claim in the case of faulty mounting
/ laying of the wire.