Installation
Connection inlet Rainwater
The connection of the rainwater inlet of the roof surface to the trident rainwater filter is
connected via a DN 110 double socket (see illustration below!).
Connection outlet to sewer
The connection of the sewer to the outlet of the Trident rainwater filter is connected via a
DN 110 tube with a single socket (see illustration below!).
Connection outlet of the filtered rainwater
The connection of the outlet of the filtered rainwater to the calmed inlet in the tank. Use a
telescopic tube for the connection of the filtered rainwater to the calmed inlet. Otherwiese,
use a DN 110 tube with a single socket to the bottom side of the filter. (see illustration
below!).
Inlet Rainwater DN 110
Outlet filtered rainwater
DN 110
!!! Filterhousing should be corrected to water level leveled after installation !!!