Herunterladen Inhalt Inhalt Diese Seite drucken

WellerFT Laserline 400V Betriebsanleitung Seite 18

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Menu navigation
FILTER TIME
RESET
5 sec
PRESSURE
CONTROL
5 sec
OFF
AUTOMATIC
5 sec
5 sec
LANGUAGE
SELECT
5 sec
UNIT NUMBER
XXXXXXXX
5 sec
北京海洋兴业科技股份有限公司(证券代码:839145) 电话:010-62176775
HOURS
DELAyED POWER-
OFF
SEK
NO
Reset filter time
Resets the elapsed filter opera-
ting hours to zero
ON
Pressure control / automatic
speed control
Intelligent control technolo-
gy, full efficiency guaranteed
Generally multiple filter-systems
tend to reduce their performance when
one filter becomes polluted. To avoid this
efficiency loss WellerFT applies intelligent
control technology. This control techno-
logy signals upcoming filter changes in
advance with an audible and visual signal
and at the same time accelerates the
power of the turbine, in order to guarantee
continuous extraction volume.
10
Automatic OFF
If this function is activated, the
unit switches automatically to
OFF mode on expiration of the
set time (the turbine and backlit display are
turned off)
Adjustable from one hour to 7 days
0
Delay time
If this function is activated, the unit
switches to OFF mode with an
delag on expiration of the set time
(the turbine and backlit display are turned off)
Adjusthalb from 0-999 seconds
GB
Selecting menu navigation
language
Select from the following user
languages:
Unit number
An internal unit number is assigned to
each unit.
D, F, E, I, GB
网址:www.hyxyyq.com
17

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für WellerFT Laserline 400V

Diese Anleitung auch für:

Laserline 200v

Inhaltsverzeichnis