SAFETY MESSAGE
Before operating the sensor, please read this manual completely, and keep it nearby for future reference.
Please follow all safety instructions in this manual for safe operation, and read it completely to prevent from injury to the
operator or causing damage to the equipment.
Note - this is a precision calibrated measuring device and should be handled with care to prevent damage from shocks
or impacts.
Safety Information
Flying particles can discharge when apply torque.
Users and bystander must wear safety goggles.
Always wear safety goggles when applying torque.
1.

MAIN FEATURES

Torque sensor with durable aluminium body for accurate torque measurement.
Mounting Holes for horoizontal or vertical fastening.
Allows connection to solid surface or mounting to CD.12A torque test bench.
USB cable connection for power and data transfer.
Accuracy is greater than ISO 6789. Refer to appendix for details.
CW and CCW Operation.
These sensors are for use either stand alone, or with FACOM CD.12A bench to allow calibration of the torque.
USB connection to a Windows device running the FACOM control software is required to communicate to the device
and display values.
2.

OPERATION

1. Select a sensor with a suitable range to cover the wrench being tested.
2. WARNING – do NOT exceed the maximum torque value of the sensor. Torque greater than 110% of the maximum
can lead to damage.
3. For greatest accuracy, sensor should be used in a temperature controlled environment. Maintain temperature for at
least 12 hours prior to conducting a calibration test.
4. Ensure the sensor is mounted securely using the provided screws, which should be fastened to the speci ed
tightening torque.
5. Connect USB cable to the controller to a suitable device. This provides both power and data transfer.
6. Ensure cable cannot snag or tangle, or otherwise interfere with safe operation.
7. Start the FACOM controller software (available from www.facom.com).
NU-EC6000_0717 ttes langues sur site.indd 7
7
07/08/2017 14:35:53