Operating elements and
functional displays
a
Display LED 1 "Operation"
LED flashes evenly
(System ramp-up)
LED flashes short on, long off
(Operation display, system is
functional)
LED flashes short on, long off
(Programming mode active)
LED remains alight
(Plug+Play programming is active)
Display LED 2 "Fault"
LED flashes long on, short off
(Own address incorrect)
LED flashes long on, short off
short on, short off, long on
(More than 31 users in the line)
LED remains alight (Address error
at other BNG/BVNG 650-...)
LED flashes evenly
In multiple line systems, more
than one ZBVG 650-... connected
LED flashes unevenly
Unsuitable device connected in
Plug+Play mode
LED flashes evenly
No BTLM/BTLE connected in
Plug+Play mode
a
Operating mode switch:
1
= Reverse compatible (with BVSG 650-...)
Norm
= Operation as a new system
b
2
= Increased range mode
c
b
In-Home bus: Video can be switched on and off.
d
c
LED 1
= Operational LED
e
LED 2
= Error LED
d
Button for programming mode ON/OFF.
f
e
Address setting from 1-15 (1-F) required in multiple-line systems.
f
Socket for connection of PRI 602-... USB, only available if ZBVG 650-...
is plugged in.
0,3s
0,3s
0,3s
1s
20ms
0,3s
2s
2s
2s
0,3s
0,3s
0,3s
0,3s
0,3s
0,2s
2s
0,3s
0,3s
0,3s
0,3s
1s
20ms
0,3s
0,3s
0,3s
0,3s
0,3s
0,3s
0,3s
0,3s
0,3s
2s
0,3s
0,3s
0,3s
etc.
1s
20ms
etc.
2s
0,3s
etc.
2s
etc.
2s
etc.
0,3s
0,3s
0,3s
etc.
0,3s
0,3s
0,2s
etc.
2s
etc.
5