OPERATION
A normal hygrostat setting (50-60%) is marked on th e console.
Min air temp 5°C.
Note : The fan stops during defrost.
The fan will start automatically, as required, on machines fi tted with LPHW and/or
remote Hygrostat.
OPERATING
a. Ensure air inlets/outlets and fi lters are kept clear and clean.
b. Wipe clean with damp cloth or cleaning fl uid suitable for painted surfaces.
Note. The Reply Paid Warranty Registration Card must be returned to ensure th e
correct warranty is given. If you do not fi nd a Registration Card with your machine,
please contact Calorex Service Department giving your name, address and serial
number of your machine, a card will th en be sent to you.

FILTER CLEANING

The fi lter can be washed in warm, soapy water, rinsed and shaken dry before
replacement. Frequency of cleaning depends on user alth ough no more th an two
month s should elapse between cleaning. The dehumidifi er must not be run with out a
fi lter fi tted.
MODEL
DUTY
DEHUMIDIFICATION
AIR HEATING (SENSIBLE) DEHUMIDIFIER ONLY
AIR HEATING (SENSIBLE) DEHUMIDIFIER & LPHW
AIR HEATING (SENSIBLE) LPHW ONLY
NOMINAL POWER CONSUMED
FAN ONLY
COMPRESSOR AND FAN
ELECTRICAL DATA
ELECTRICAL SUPPLY
MAX FUSE RATING
NOMINAL RUNNING AMPS
FULL LOAD AMPS (MIN SUPPLY CAPACITY)
COMPRESSOR LRA
AIR DATA
AIR FLOW (NOMINAL) HIGH SPEED
LOW SPEED
WATER DATA
LPHW FLOW RATE
LPHW PRESSURE DROP
LPHW COIL VOLUME
GENERAL DATA
HERMETIC SYSTEM
REFRIGERANT CHARGE
SOUND PRESSURE LEVEL @ 1m
DIMENSIONS
WIDTH
(UNPACKED)
DEPTH
(UNPACKED)
HEIGHT
(UNPACKED)
WEIGHT
(UNPACKED) STD/LPHW
WIDTH
(PACKED)
DEPTH
(PACKED)
HEIGHT
(PACKED)
WEIGHT
(PACKED)
Global Warming Potential R407c 1774.
DH75AX
L/hr
3,6
kW
4,7
kW
11,3
kW
8,9
kW
0,16
kW
1,46
230V ~1N 50Hz
AMP
13
AMP
6,4
AMP
7,8
AMP
55
m³/h
925
m³/h
750
L/min
9,6
m hd
2,80
L
0,63
R407c
kg
2
dB(A)
53
mm
1520
mm
385
mm
796
kg
143/147
mm
1575
mm
420
mm
932
STD/LPHW
kg
163/167
MACHINE NOT RUNNING AT ALL.
CHECK THE FOLLOWING.
1. Is supply switched on?
2. Is supply fuse health y?
3. Turn Hygrostat knob fully anti-clockwise.
4. Check air inlet and outlet for obstructions and th at fi lter is not blocked.
5. Check th at HP and LP switch are reset.
6. If, aft er carrying out th e above and waiting 30 mins, th e machine does not start,
telephone for service.
MACHINE FAN ONLY RUNNING (No LPHW demand)?
7. Turn Hygrostat knob fully anti-clockwise.
8. Check air inlet and outlet for obstructions and th at fi lter is not blocked.
9. Check th at HP and LP switch are reset, if aft er 30 mins th e machine has not
restarted, telephone for service.
WATER LEAKING FROM BASE OF UNIT
10. Check connection from machine to drain for blockages and clear accordingly.
Check fall is adequate.
11. Check th at machine is level both vertically and horizontally.
The user check list should be carried out before initiating a service call. Do not attempt
to interfere with any internal control settings as th ese have been factory calibrated and
sealed.
If in doubt or if advice is required, contact Calorex Service Department. Telephone
(01621)857171 or 856611.
DH110AX
DH110BX
TTW75AX
4,5
4,5
6,4
6,4
12,2
12,2
11,3
8,9
8,9
0,16
0,16
0,16
2,12
1,94
1,46
400V ~3N
230V ~1N
50Hz
50Hz
16
10
9,3
4,2
10,6
5,0
66
30
1007
1007
812
812
9,6
9,6
2,80
2,80
2,80
0,63
0,63
0,63
2
2
53
53
1520
1520
1474
385
385
796
796
1167
144/148
144/148
143/147
1575
1575
1575
420
420
932
932
164/168
164/168
163/167
TTW110AX
TTW110BX
3,6
4,5
4,7
6,4
12,2
8,9
8,9
0,16
2,12
230V ~1N 50Hz
400V ~3N 50Hz
13
16
6,4
9,3
7,8
10,6
55
66
925
1007
750
812
9,6
9,6
2,80
0,63
2
2
53
53
1474
350
350
1167
144/148
1575
420
420
932
932
164/168
4,5
6,4
12,2
8,9
0,16
1,94
10
4,2
5,0
30
1007
812
9,6
2,80
0,63
2
53
1474
350
1167
143/147
1575
420
932
163/167

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dh110axTtw110axTtw75axDh110bxTtw110bx

Inhaltsverzeichnis